Part Number | 101190684 |
---|---|
Manufacturer | SCHMERSAL |
Category | Safety » Controllers |
Price | Request Quote |
Lead Time | Request Quote |
Safety Controller, 24VDC, General Purpose, 3 Safety Contacts, 1 Signalling Output
Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.
Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.
Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.
Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.
Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.
Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.
After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.
IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.
Do you need a 101190684? We can help you find it at a competitive price!
Part Number | 101190684 |
---|---|
Product Series | SRB |
Voltage | 24VDC |
Weight - lbs. | 0.5500 |
Base Unit of Measure | Each |
Categorization Information | Safety - Intrinsic, Curtains, Mats, etc. Safety Controller, 24VDC, General Purpose,-101190684 |
Download "schmersal-srb-threeoonemc-twentyfourv-datasheet.pdf" (231 KiB)
17.02.2016 - 22:07:05h Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Preferred typ • Fit for signal evaluation of outputs of safety magnetic switches • 3 safety contacts, STOP 0 • 1 Signalling output • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks (Minor differences between the printed image and the original product may exist!) Ordering details Product type description SRB 301MC-24V Article number 101190684 EAN code 4030661356082 eCl@ss 27-37-19-01 Approval Approval BG USA/CAN Classification Standards EN ISO 13849-1, IEC 61508, EN 60947-5-1 PL up e (STOP 0) Control category up 4 (STOP 0) DC 99% (STOP 0) CCF > 65 points PFH value ≤ 2,0 x 10-8/h (STOP 0) SIL up 3 (STOP 0) Mission time 20 Years - notice The PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n-op/y). In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts. Diverging applications on request. Global Properties Product name SRB 301MC Standards IEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508 Compliance with the Directives (Y/N) Yes Climatic stress EN 60068-2-78 Mounting snaps onto standard DIN rail to EN 60715 Terminal designations IEC/EN 60947-1 Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, ventilated - Material of the contacts , Ag-Ni, self-cleaning, positive action Weight 250 g Start conditions Automatic or Start button Start input (Y/N) Yes Feedback circuit (Y/N) Yes Start-up test (Y/N) No Automatic reset function (Y/N) Yes Reset with edge detection (Y/N) No Pull-in delay - ON delay with automatic start 100 ms - ON delay with reset button 20 ms Drop-out delay - Drop-out delay in case of power failure 80 ms - Drop-out delay in case of emergency stop ≤ 20 ms Mechanical data Connection type Screw connection Cable section - Min. Cable section 0,25 mm² - Max. Cable section 2.5 mm² Pre-wired cable rigid or flexible Tightening torque for the terminals 0,6 Nm Detachable terminals (Y/N) No Mechanical life 10.000.000 operations Electrical lifetime Derating curve available on request restistance to shock 30 g / 11 ms Resistance to vibration To EN 60068-2-6 10...55 Hz, Amplitude 0,35 mm, ± 15 % Ambient conditions Ambient temperature - Min. environmental temperature −25 °C - Max. environmental temperature +60 °C Storage and transport temperature - Min. Storage and transport temperature −40 °C - Max. Storage and transport temperature +85 °C Protection class - Protection class-Enclosure IP40 - Protection class-Terminals IP20 - Protection class-Clearance IP54 Air clearances and creepage distances To IEC/EN 60664-1 - Rated impulse withstand voltage Uimp 4 kV - Overvoltage category III To IEC/EN 60664-1 - Degree of pollution 2 To IEC/EN 60664-1 Electromagnetic compatibility (EMC) EMC rating conforming to EMC Directive Electrical data Rated DC voltage for controls - Min. rated DC voltage for controls 20.4 V - Max. rated DC voltage for controls 28.8 V Rated AC voltage for controls, 50 Hz - Min. rated AC voltage for controls, 50 Hz 20.4 V - Max. rated AC voltage for controls, 50 Hz 26.4 V Rated AC voltage for controls, 60 Hz - Min. rated AC voltage for controls, 60 Hz 20.4 V - Max. rated AC voltage for controls, 60 Hz 26.4 V Contact resistance max. 100 mΩ Power consumption 2 W; 4.9 VA Type of actuation AC/DC Switch frequency Rated operating voltage Ue 24 VDC −15% / +20%, residual ripple max. 10% 24 VAC −15% / +10% Operating current Ie Frequency range 50 / 60 Hz Electronic protection (Y/N) Yes Fuse rating for the operating voltage Internal electronic trip, tripping current > 0,5 A, Reset after approximately 1 second/s Current and tension on control circuits - S11, S12, S21, S22 24 VDC, Test current: 10 mA Bridging in case of voltage drops 80 ms Inputs Monitored inputs - Short-circuit recognition (Y/N) optional - Wire breakage detection (Y/N) Yes - Earth connection detection (Y/N) Yes Number of shutters 0 piece Number of openers 2 piece Cable length 1500 m with 1.5 mm²; 2500 m with 2.5 mm² Conduction resistance max. 40 Ω Outputs Stop category 0 / 1 Number of safety contacts 3 piece Number of auxiliary contacts 1 piece Number of signalling outputs 0 piece Switching capacity - Switching capacity of the safety contacts max. 250 VAC, 8 A ohmic (inductive in case of appropriate protective wiring) min. 10 V / 10 mA - Switching capacity of the auxiliary contacts 24 VDC, 2 A Fuse rating - Protection of the safety contacts 8 A slow blow - Fuse rating for the auxiliary contacts 2 A slow blow Utilisation category To EN 60947-5-1 AC-15: 230 V / 6 A DC-13: 24 V / 6 A Number of undelayed semi-conductor outputs with signaling function 0 piece Number of undelayed outputs with signaling function (with contact) 1 piece Number of delayed semi-conductor outputs with signaling function. 0 piece Number of delayed outputs with signalling function (with contact). 0 piece Number of secure undelayed semi-conductor outputs with signaling function 0 piece Number of secure, undelayed outputs with signaling function, with contact. 3 piece Number of secure, delayed semi-conductor outputs with signaling function 0 piece Number of secure, delayed outputs with signaling function (with contact). 0 piece LED switching conditions display LED switching conditions display (Y/N) Yes Number of LED´s 4 piece LED switching conditions display - The integrated LEDs indicate the following operating states. - Position relay K1 - Position relay K2 - Supply voltage - Internal operating voltage Ui Miscellaneous data Applications Emergency-Stop button Guard system Pull-wire emergency stop switches Safety light curtain Safety sensor Dimensions Dimensions - Width 22.5 mm - Height 100 mm - Depth 121 mm notice Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. notice - Wiring example To secure a guard door up to PL 4 and Category #03# Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range The feedback circuit monitors the position of the contactors Ka and Kb. Switch setting: The cross-wire short detection function (factory default) is programmed by means of the switch located underneath the front cover of the module: Pposition nQS (top): no cross-wire short protection, suitable for 1-channel applications and applications with outputs with potential in the control circuits. Position QS (bottom): cross-wire short protection, suitable for 2-channel applications without outputs with potential in the control circuits. For 1-channel control, connect NC contact to S11/S12 and bridge S12/S22 (QS-switch = nQS) Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential. (QS-switch = nQS) Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge The wiring diagram is shown with guard doors closed and in de-energised condition. Documents Operating instructions and Declaration of conformity (jp) 461 kB, 03.07.2013 Code: mrl_srb_301mc_jp Operating instructions and Declaration of conformity (fr) 380 kB, 01.10.2015 Code: mrl_srb_301mc_fr Operating instructions and Declaration of conformity (pl) 387 kB, 26.11.2014 Code: mrl_srb_301mc_pl Operating instructions and Declaration of conformity (en) 377 kB, 24.09.2015 Code: mrl_srb_301mc_en Operating instructions and Declaration of conformity (it) 379 kB, 01.10.2015 Code: mrl_srb_301mc_it Operating instructions and Declaration of conformity (br) 830 kB, 28.10.2010 Code: mrl_srb_301mc_br Operating instructions and Declaration of conformity (pt) 384 kB, 13.10.2015 Code: mrl_srb_301mc_pt Operating instructions and Declaration of conformity (es) 373 kB, 24.11.2015 Code: mrl_srb_301mc_es Operating instructions and Declaration of conformity (de) 387 kB, 24.09.2015 Code: mrl_srb_301mc_de Operating instructions and Declaration of conformity (nl) 361 kB, 08.07.2013 Code: mrl_srb_301mc_nl Wiring example (99) 17 kB, 04.08.2008 Code: ksrb3l18 Declaration of conformity (de) 102 kB, 13.07.2015 Code: KONFI_mrl_srb_301mc_de TÜV certification (de, en) 556 kB, 31.03.2011 Code: z_srbp01 CCC certification (en) 104 kB, 20.11.2015 Code: q_srbp03 CCC certification (cn) 95 kB, 20.11.2015 Code: q_srbp04 EAC certification (ru) 833 kB, 05.10.2015 Code: q_6042p17_ru Images Wiring example K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 17.02.2016 - 22:07:05h Kasbase 3.2.1.F.64I