Part Number LPCI-COM422-8
Manufacturer PORTWELL
Category I/O Products
Price Request Quote
Lead Time Request Quote

Description

Low Profile Eight-port asynchronous RS-422 serial communication card that can be installed in any 3.3V or 5V PCI slot computer. Supports RS-422 protocol under all OS at baud rates up to 921Kbps

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a LPCI-COM422-8? We can help you find it at a competitive price!

Specifications

Categorization Information IO Products

Features

  • Universal PCI, PCI-X, 3.3V and 5V compatible
  • Eight-Port, RS-422 or RS-485 protocols
  • Speeds up to 921Kbps
  • Include type 16550 UARTs (optional 16850)
  • Meets MD2 Low Profile PCI Bus Specification
  • Breakout cable provides DB9 connectors for each port (no external breakout box required)
  • RoHS compliant versions available

Datasheet

Download "LPCI-COM422-8.pdf" (506 KiB)

Extracted Text

MODEL LPCI-COM422/8 USER MANUAL FILE: MLPCI-COM422-8.D1j Notice The information in this document is provided for reference only. Portwell does not assume any liability arising out of the application or use of the information or products described herein. This document may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of Portwell, nor the rights of others. IBM PC, PC/XT, and PC/AT are registered trademarks of the International Business Machines Corporation. Printed in USA. Copyright 1995, 2006 by Portwell I/O Products Inc. All rights reserved. WARNING!! ALWAYS CONNECT AND DISCONNECT YOUR FIELD CABLING WITH THE COMPUTER POWER OFF. ALWAYS TURN COMPUTER POWER OFF BEFORE INSTALLING A CARD. CONNECTING AND DISCONNECTING CABLES, OR INSTALLING CARDS INTO A SYSTEM WITH THE COMPUTER OR FIELD POWER ON MAY CAUSE DAMAGE TO THE I/O CARD AND WILL VOID ALL WARRANTIES, IMPLIED OR EXPRESSED. 2 Manual LPCI-COM422/8 Warranty Prior to shipment, Portwell equipment is thoroughly inspected and tested to applicable specifications. However, should equipment failure occur, Portwell assures its customers that prompt service and support will be available. All equipment originally manufactured by Portwell which is found to be defective will be repaired or replaced subject to the following considerations. Terms and Conditions If a unit is suspected of failure, contact Portwell' Customer Service department. Be prepared to give the unit model number, serial number, and a description of the failure symptom(s). We may suggest some simple tests to confirm the failure. We will assign a Return Material Authorization (RMA) number which must appear on the outer label of the return package. All units/components should be properly packed for handling and returned with freight prepaid to the Portwell designated Service Center, and will be returned to the customer's/user's site freight prepaid and invoiced. Coverage First Three Years: Returned unit/part will be repaired and/or replaced at Portwell option with no charge for labor or parts not excluded by warranty. Warranty commences with equipment shipment. Following Years: Throughout your equipment's lifetime, Portwell stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry. Equipment Not Manufactured by Portwell Equipment provided but not manufactured by Portwell is warranted and will be repaired according to the terms and conditions of the respective equipment manufacturer's warranty. General Under this Warranty, liability of Portwell is limited to replacing, repairing or issuing credit (at Portwell discretion) for any products which are proved to be defective during the warranty period. In no case is Portwell liable for consequential or special damage arriving from use or misuse of our product. The customer is responsible for all charges caused by modifications or additions to Portwell equipment not approved in writing by Portwell or, if in Portwell opinion the equipment has been subjected to abnormal use. "Abnormal use" for purposes of this warranty is defined as any use to which the equipment is exposed other than that use specified or intended as evidenced by purchase or sales representation. Other than the above, no other warranty, expressed or implied, shall apply to any and all such equipment furnished or sold by Portwell. 3 Manual LPCI-COM422/8 Table of Contents Chapter 1: Introduction ..............................................................................................................................5 Specifications..........................................................................................................................................6 Figure 1-1: Block Diagram(Only one serial channel shown)...............................................................7 Chapter 2: Installation ................................................................................................................................8 Chapter 3: Option Selection.....................................................................................................................11 Figure 3-1: Simplified Termination Schematic ..................................................................................11 Figure 3-2: Option Selection Map......................................................................................................12 Chapter 4: Address Selection..................................................................................................................13 Chapter 5: Programming..........................................................................................................................14 Table 5-1: Baud Rate Divisor Values.................................................................................................15 Chapter 6: Connector Pin Assignments.................................................................................................18 Table 6-1: Connection Pin Assignments ...........................................................................................18 Table 6-2: Data Cable Wiring ............................................................................................................19 Appendix A: Application Considerations...............................................................................................20 Table A-1: Connections Between Two RS422 Devices ....................................................................20 Table A-2: RS422 Specification Summary ........................................................................................21 Figure A-1: Typical RS485 Two-Wire Multidrop Network .................................................................22 4 Manual LPCI-COM422/8 Chapter 1: Introduction The card was designed for effective multipoint transmission in RS422 (EIS422) protocol. The card is 6.60 inches long and may be installed in an available 5V or 3.3V PCI expansion slot. The card features eight independent, asynchronous RS422 serial ports and type 16550 buffered UARTs. The card meets Universal PCI and MD2 Low Profile PCI Bus Specifications. RS422 Balanced Mode Operation The card supports RS422 communications and uses differential balanced drivers for long range and noise immunity. It also has the capability to add load resistors to terminate the communications lines. RS422 communications requires that a transmitter supply a bias voltage to ensure a known "zero" state. Also, receiver inputs at each end of the network should be terminated to eliminate "ringing". The card supports biasing by default and supports termination by jumpers on the card. If your application requires the transmitter to be un-biased, please contact the factory. COM Port Compatibility Type 16550 UARTs are used as the Asynchronous Communication Element (ACE). These include 16- byte transmit/receive buffers to protect against lost data in multitasking operating systems, while maintaining 100% compatibility with the original IBM serial port. The system assigns the address(es). A crystal oscillator is located on the card. This oscillator permits precise selection of baud rates up to 115,200 or, by changing a jumper, up to 921,600 with the standard crystal oscillator. The driver/receiver used, the SN75176B, is capable of driving extremely long communication lines at high baud rates. It can drive up to +60 mA on balanced lines and receive inputs as low as 200 mV differential signal superimposed on common mode noise of +12 V or -7 V. In case of communication conflict, the driver/receivers feature thermal shutdown. Communication Mode The card supports Full-Duplex and Half-Duplex communications with a 4-wire cable connection. Half- Duplex allows traffic to travel in both directions, but only one way at a time. Baud Rate Ranges The card has capability for two baud rate ranges and you can select which you wish to use on a port-by- port basis. One range is up to 115,200 baud applications and the other is up to 921,600 baud. Refer to Table 5-1, Baud Rate Divisor Values in chapter 5 of the manual. 5 Manual LPCI-COM422/8 Specifications Communications Interface • I/O Connection: 50-pin SCSI D-Connector • Serial Ports: Eight cable terminated shielded male D-sub 9-pin with standard IBM AT Style connectors compatible with RS422 specifications • Character length: 5, 6, 7, or 8 bits • Parity: Even, odd or none • Stop Interval: 1, 1.5, or 2 bits • Serial Data Rates: Up to 115,200 baud, Asynchronous, A faster range of rates, up to 921,600, is achieved by jumper selection on the card. Type 16550 buffered UART • Address: Continuously mappable within 0000 to FFFF (hex) range of PCI bus addresses • Receiver Input Sensitivity: +200 mV, differential input • Common Mode Rejection: +12V to -7V • Transmitter Output Drive Capability: 60 mA, with thermal shutdown Environmental • Operating Temperature Range: 0°C to +60°C • Storage temperature Range: -50°C to +120°C • Humidity: 5% to 95%, non-condensing • Power Required: +5VDC at 200 mA typical • Size: Low Profile Version: 6.6” long (167.64mm) by 2.21” tall (56.17mm) seated height. 6 Manual LPCI-COM422/8 SCSI-2 CONNECTOR HPBR-2150 OR EQUIVALENT (HALF-PITCH 50-PIN) Figure 1-1: Block Diagram(Only one serial channel shown) 7 Manual LPCI-COM422/8 Chapter 2: Installation A printed Quick-Start Guide (QSG) is packed with the card for your convenience. If you’ve already performed the steps from the QSG, you may find this chapter to be redundant and may skip forward to begin developing your application. The software provided with this card is on CD and must be installed onto your hard disk prior to use. To do this, perform the following steps as appropriate for your operating system. Configure Card Options via Jumper Selection Before installing the card into your computer, carefully read Chapter 3: Option Selection of this manual, then configure the card according to your requirements and protocol (RS-232, RS-422, RS-485, 4-wire 485, etc.). Our Windows based setup program can be used in conjunction with Chapter 3 to assist in configuring jumpers on the card, as well as provide additional descriptions for usage of the various card options (such as termination, bias, baud rate range, RS-232, RS-422, RS-485, etc.). CD Software Installation The following instructions assume the CD-ROM drive is drive “D”. Please substitute the appropriate drive letter for your system as necessary. DOS 1. Place the CD into your CD-ROM drive. 2. Type B- to change the active drive to the CD-ROM drive. 3. Type GLQR?JJ- to run the install program. 4. Follow the on-screen prompts to install the software for this board. WINDOWS 1. Place the CD into your CD-ROM drive. 2. The system should automatically run the install program. If the install program does not run promptly, click START | RUN and type BGLQR?JJ, click OK or press -. 3. Follow the on-screen prompts to install the software for this board. LINUX 1. Please refer to linux.htm on the CD-ROM for information on installing under linux. Note: COM boards can be installed in virtually any operating system. We do support installation in earlier versions of Windows, and are very likely to support future versions as well. Caution! * ESD A single static discharge can damage your card and cause premature failure! Please follow all reasonable precautions to prevent a static discharge such as grounding yourself by touching any grounded surface prior to touching the card. 8 Manual LPCI-COM422/8 Hardware Installation 1. Make sure to set switches and jumpers from either the Option Selection section of this manual or from the suggestions of SETUP.EXE. 2. Do not install card into the computer until the software has been fully installed. 3. Turn OFF computer power AND unplug AC power from the system. 4. Remove the computer cover. 5. Carefully install the card in an available 5V or 3.3V PCI expansion slot (you may need to remove a backplate first). 6. Inspect for proper fit of the card and tighten screws. Make sure that the card mounting bracket is properly screwed into place and that there is a positive chassis ground. 7. Install an I/O cable onto the card’s bracket mounted connector. 8. Replace the computer cover and turn ON the computer. Enter the CMOS setup program of your system and verify that the PCI plug-and-play option is set appropriately for your system. Systems running Windows 95/98/2000/XP/2003 (or any other PNP-compliant operating system) should set the CMOS option to OS. Systems running under DOS, Windows NT, Windows 3.1, or any other non-PNP-compliant operating system should set the PNP CMOS option to BIOS or Motherboard. Save the option and continue booting the system. 9. Most computers should auto-detect the card (depending on the operating system) and automatically finish installing the drivers. 10. Run PCIfind.exe to complete installing the card into the registry (for Windows only) and to determine the assigned resources. 11. Run one of the provided sample programs that was copied to the newly created card directory (from the CD) to test and validate your installation. The base address assigned by BIOS or the operating system can change each time new hardware is installed into or removed from the computer. Please recheck PCIFind or Device Manager if the hardware configuration is changed. Software you write can automatically determine the base address of the card using a variety of methods depending on the operating system. In DOS, the PCI\SOURCE directory shows the BIOS calls used to determine the address and IRQ assigned to installed PCI devices. In Windows, the Windows sample programs demonstrate querying the registry entries (created by PCIFind and NTIOPCI.SYS during boot-up) to determine this same information. 9 Manual LPCI-COM422/8 Interrupts Please note that, in Windows NT, changes must be made to the system registry to support IRQ sharing. The following is excerpted from "Controlling Multiport Serial I/O Cards" provided by Microsoft in the MSDN library, documentid:mk:@ivt:nt40res/D15/S55FC.HTM, also available in the WindowsNT Resource Kit. The Microsoft serial driver can be used to control many dumb multiport serial cards. Dumb indicates that the control includes no on-board processor. Each port of a multiport card has a separate subkey under the HKLM\CurrentControlSet\Services\Serial\Parameters subkey in the registry. In each of these subkeys, you must add values for DosDevices, Interrupt, InterruptStatus, PortAddress, and PortIndex because these are not detected by the Hardware Recognizer. (For descriptions and ranges for these values, see Regentry.hlp, the Registry help file on the WindowsNT Workstation Resource Kit CD.) For example, if you have an eight-port card configured to use address 0xFC00 with an interrupt of 05, the values in the Registry are: Serial##### Subkey: Serial##### Subkey: PortAddress = REG_DWORD 0xFC00 PortAddress = REG_DWORD 0xFC20 Interrupt = REG_WORD 5 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM5 DosDevices = REG_SZ COM9 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 1 PortIndex - REG_DWORD 5 Serial##### Subkey: Serial##### Subkey: PortAddress = REG_DWORD 0xFC00 PortAddress = REG_DWORD 0xFC20 Interrupt = REG_WORD 5 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM5 DosDevices = REG_SZ COM9 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 1 PortIndex - REG_DWORD 5 Serial##### Subkey: Serial##### Subkey: PortAddress = REG_DWORD 0xFC08 PortAddress = REG_DWORD 0xFC28 Interrupt = REG_DWORD 5 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM6 DosDevices = REG_SZ COM10 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 2 PortIndex = REG_DWORD 6 Serial##### Subkey: Serial##### Subkey: PortAddress =_DWORD 0xFC10 PortAddress = REG_DWORD 0xFC30 Interrupt = REG_DWORD 5 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM7 DosDevices = REG_SZ COM11 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex - REG_DWORD 3 PortIndex = REG_DWORD 7 Serial##### Subkey: Serial##### Subkey: PortAddress = REG_DWORD 0xFC18 PortAddress = REG_DWORD 0xFC38 Interrupt = REG_DWORD 5 Interrupt = REG_DWORD 5 Dos Devices = REG_SZ COM8 DosDevices = REG_SZ COM12 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD4 PortIndex = REG_DWORD8 As this example shows, the shared IRQ status Register is located at Base address + 0x40. 10 Manual LPCI-COM422/8 Chapter 3: Option Selection To help you locate the jumpers described in this section, refer to the Option Selection Map at the end of this section. Operation of the serial communications section is determined by jumper installation as described in the following paragraphs. Terminations A transmission line should be terminated at the receiving end in its characteristic impedance. Installing a jumper at the locations labeled LOAD INPUT apply a 120Ω load across the receive input for RS422 operation. Rx+ “A” through “H” 120 0.1 F : Rx- Figure 3-1: Simplified Termination Schematic Data Cable Wiring SignalPin Connection Ain- 1 Aout+ 2 Aout- 3 100 Ω to Ground 5 Ain+ 9 Baud Rate Ranges The jumper labeled X8CLK is provided to select baud rates in either of two ranges. When not installed, the baud rate range is up to 115,200 baud. When installed in the X8CLK, the baud rate range is 200 to 921,600 baud. 11 Manual LPCI-COM422/8 6.60" LOAD A B C D BAUD x8 E F G H Figure 3-2: Option Selection Map 12 Manual LPCI-COM422/8 2.20" Chapter 4: Address Selection The card uses one address space. COM A, COM B, COM C, COM D, COM E, COM F, COM G, and COM H each occupy eight consecutive register locations. The interrupt register which indicates which port or ports caused the interrupt is located at base address + 64. PCI architecture is Plug and Play. This means that the BIOS or Operating System determines the resources assigned to PCI cards rather than you selecting those resources with switches or jumpers. As a result, you cannot set or change the card's base address. You can only determine what the system has assigned. To determine the base address that has been assigned, run the PCIFind.EXE, or PCINT utility program provided. This utility will display a list of all of the cards detected on the PCI bus, the addresses assigned to each function on each of the cards, and the respective IRQs (if any) allotted. Alternatively, some operating systems (Plug and Play Windows) can be queried to determine which resources were assigned. In these operating systems, you can use either PCIFind or the Device Manager utility from the System Applet of the control panel. The card is installed in the Data Acquisition class of the Device Manager list. Selecting the card, clicking Properties, and then selecting the Resources Tab will display a list of the resources allocated to the card. The PCI bus supports 64K of I/O space, so your card's addresses may be located anywhere in the 0000 to FFFF hex range. Vendor ID code is 494F (ASCII for "I/O") Device ID code is 1068 13 Manual LPCI-COM422/8 Chapter 5: Programming Sample Programs There are sample programs provided with the card in C, Pascal, QuickBASIC, and several Windows languages. DOS samples are located in the DOS directory and Windows samples are located in the WIN32 directory. Windows Programming The card installs into Windows as COM ports. Thus the Windows standard API functions can be used. In particular: ► CreateFile() and CloseHandle() for opening and closing a port. ► SetupComm(), SetCommTimeouts(), GetCommState(), and SetCommState() to set and change a port’s settings. ► ReadFile() and WriteFile() for accessing a port. See the documentation for your chosen language for details. Under DOS, the process is very different. The remainder of this chapter describes DOS programming. 14 Manual LPCI-COM422/8 Initialization Initializing the chip requires knowledge of the UART's register set. The first step is to set the baud rate divisor. You do this by first setting the DLAB (Divisor Latch Access Bit) high. This bit is Bit 7 at Base Address +3. In C code, the call would be: outportb(BASEADDR +3,0x80); You then load the divisor into Base Address +0 (low byte) and Base Address +1 (high byte). The following equation defines the relationship between baud rate and divisor: desired baud rate = (UART clock frequency) / (32 * divisor) On the card, the UART clock frequency is 1.8432 MHz. On the next page is a table for the popular divisor frequencies. Baud Rate Divisor x1 Divisor x8 Max Diff. Cable Length* 921600 - 1 250 ft 460800 - 2 550 ft 230400 - 4 1400 ft 153600 - 6 2500 ft 115200 1 8 3000 ft 57600 2 16 4000 ft 38400 3 24 4000 ft 28800 4 32 4000 ft 19200 6 48 4000 ft 14400 8 64 4000 ft 9600 12 96 – Most Common 4000 ft 4800 24 192 4000 ft 2400 48 384 4000 ft 1200 96 768 4000 ft * These are theoretical maximums for typical conditions and good quality cables based on the EIA 485 and EIA 422 standard for balanced differential drivers. Table 5-1: Baud Rate Divisor Values In C, the code to set the chip to 9600 baud is: outportb(BASEADDR, 0x0C); outportb(BASEADDR +1,0); The second initializing step is to set the Line Control Register at Base Address +3. This register defines word length, stop bits, parity, and the DLAB. Bits 0 and 1 control word length and allow word lengths from 5 to 8 bits. Bit settings are extracted by subtracting 5 from the desired word length. Bit 2 determines the number of stop bits. There can be either one or two stop bits. If Bit 2 is set to 0, there will be one stop bit. If Bit 2 is set to 1, there will be two stop bits. Bits 3 through 6 control parity and break enable. They are not commonly used for communications and should be set to zeroes. 15 Manual LPCI-COM422/8 Bit 7 is the DLAB discussed earlier. It must be set to zero after the divisor is loaded or else there will be no communications. The C command to set the UART for an 8-bit word, no parity, and one stop bit is: outportb(BASEADDR +3, 0x03) Reception Reception can be handled in two ways: polling and interrupt-driven. When polling, reception is accomplished by constantly reading the Line Status Register at Base Address +5. Bit 0 of this register is set high whenever data are ready to be read from the chip. A simple polling loop must continuously check this bit and read in data as it becomes available. The following code fragment implements a polling loop and uses a value of 13, (ASCII Carriage Return) as an end-of-transmission marker: do { while (!(inportb(BASEADDR +5) & 1)); /*Wait until data ready*/ data[i++]= inportb(BASEADDR); } while (data[i]!=13); /*Reads the line until null character rec'd*/ Interrupt-driven communications should be used whenever possible and is required for high data rates. Writing an interrupt-driven receiver is not much more complex than writing a polled receiver but care should be taken when installing or removing your interrupt handler to avoid writing the wrong interrupt, disabling the wrong interrupt, or turning interrupts off for too long a period. The handler would first read the Interrupt Identification Register at Base Address +2. If the interrupt is for Received Data Available, the handler then reads the data. If no interrupt is pending, control exits the routine. A sample handler, written in C, is as follows: readback = inportb(BASEADDR +2); if (readback & 4) /*Readback will be set to 4 if data are available*/ data[i++]=inportb(BASEADDR); outportb(0x20,0x20); /*Write EOI to 8259 Interrupt Controller*/ return; 16 Manual LPCI-COM422/8 Transmission To transmit a string of data, the transmitter must first check Bit 5 of the Line Status Register at Base Address +5. That bit is the transmitter-holding-register-empty flag. If it is high, the transmitter has sent the data. The process of checking the bit until it goes high followed by a write is repeated until no data remains. The following C code fragment demonstrates this process: while(data[i]); /*While there is data to send*/ { while(!(inportb(BASEADDR +5)&0x20)); /*Wait until transmitter is empty*/ outportb(BASEADDR,data[i]); i++; } 17 Manual LPCI-COM422/8 Chapter 6: Connector Pin Assignments Input/Output Connections The card uses a 50-pin SCSI D-connector to interface to a spider cable. The spider cable has eight individual DB9M connectors provided with it. To ensure that there is minimum susceptibility to EMI and minimum radiation it is important that the card mounting bracket be properly screwed into place and that there be a positive chassis ground. Also, proper EMI cabling techniques (cable connect to chassis ground at the aperture, shielded twisted-pair wiring, etc) must be used for the input/output wiring. Pin RS-422 Signals Pin RS-422 Signals 1 GND Ground 26GND Ground 2 Aout+ 27Eout+ 3 Aout- 28Eout- 4 Ground through 100 Ohm R 29 Ground through 100 Ohm R 5 Ain+ 30Ein+ 6 Ain- 31Ein- 7 GND Ground 32GND Ground 8 Bout+ 33Fout+ 9 Bout- 34Fout- 10 Ground through 100 Ohm R 35 Ground through 100 Ohm R 11 Bin+ 36 Fin+ 12 Bout- 37 Fout- 13 GND Ground 38 GND Ground 14 Cout+ 39 Gout+ 15 Cout- 40 Gout- 16 Ground through 100 Ohm R 41 Ground through 100 Ohm R 17 Cin+ 42 Gin+ 18 Cin- 43 Gin- 19 GND Ground 44 GND Ground 20 Dout+ 45 Hout+ 21 Dout- 46 Hout- 22 Ground through 100 Ohm R 47 Ground through 100 Ohm R 23 Din+ 48 Hin+ 24 Din- 49 Hin- 25 GND Ground 50 GND Ground Table 6-1: Connection Pin Assignments 18 Manual LPCI-COM422/8 Signal Connector Pin Ain- Pin 1 Aout+ Pin 2 Aout- Pin 3 100 Ohm to Ground Pin 5 Ain+ Pin 9 Table 6-2: Data Cable Wiring 19 Manual LPCI-COM422/8 Appendix A: Application Considerations Introduction Working with RS422 and RS485 devices is not much different from working with standard RS232 serial devices and these two standards overcome deficiencies in the RS232 standard. First, the cable length between two RS232 devices must be short; less than 50 feet at 9600 baud. Second, many RS232 errors are the result of noise induced on the cables. The RS422 standard permits cable lengths up to 5000 feet and, because it operates in the differential mode, it is more immune to induced noise. Connections between two RS422 devices (with CTS ignored) should be as follows: Device #1 Device #2 Signal Pin No.Signal Pin No. Gnd 7 Gnd 7 + + TX 24 RX 12 - - TX 25 RX 13 + + RX 12 TX 24 - - RX 13 TX 25 Table A-1: Connections Between Two RS422 Devices A third deficiency of RS232 is that more than two devices cannot share the same cable. This is also true for RS422 but RS485 offers all the benefits of RS422 plus allows up to 32 devices to share the same twisted pairs. An exception to the foregoing is that multiple RS422 devices can share a single cable if only one will talk and the others will all receive. Balanced Differential Signals The reason that RS422 and RS485 devices can drive longer lines with more noise immunity than RS232 devices is that a balanced differential drive method is used. In a balanced differential system, the voltage produced by the driver appears across a pair of wires. A balanced line driver will produce a differential voltage from +2 to +6 volts across its output terminals. A balanced line driver can also have an input "enable" signal that connects the driver to its output terminals. If the "enable signal is OFF, the driver is disconnected from the transmission line. This disconnected or disabled condition is usually referred to as the "tristate" condition and represents a high impedance. RS485 drivers must have this control capability. RS422 drivers may have this control but it is not always required. A balanced differential line receiver senses the voltage state of the transmission line across the two signal input lines. If the differential input voltage is greater than +200 mV, the receiver will provide a specific logic state on its output. If the differential voltage input is less than -200 mV, the receiver will provide the opposite logic state on its output. A maximum operating voltage range is from +6V to -6V allows for voltage attenuation that can occur on long transmission cables. A maximum common mode voltage rating of +7V provides good noise immunity from voltages induced on the twisted pair lines. The signal ground line connection is necessary in order to keep the common mode voltage within that range. The circuit may operate without the ground connection but may not be reliable. 20 Manual LPCI-COM422/8 Parameter Conditions Min. Max. Driver Output Voltage (unloaded) 4V 6V -4V -6V Driver Output Voltage (loaded) LD and LDGND 2V jumpers in -2V Driver Output Resistance 50Ω Driver Output Short-Circuit Current +150 mA Driver Output Rise Time 10% unit interval Receiver Sensitivity +200 mV Receiver Common Mode Voltage +7V Range Receiver Input Resistance 4KΩ Table A-2: RS422 Specification Summary To prevent signal reflections in the cable and to improve noise rejection in both the RS422 and RS485 mode, the receiver end of the cable should be terminated with a resistance equal to the characteristic impedance of the cable. (An exception to this is the case where the line is driven by an RS422 driver that is never "tristated" or disconnected from the line. In this case, the driver provides a low internal impedance that terminates the line at that end.) Note You do not have to add a terminator resistor to your cables when you use the card. Termination resistors for the RX+ and RX- lines are provided on the card and are placed in the circuit when you install the LD and LDGND jumpers. (See the Option Selection section of this manual.) RS485 Data Transmission The RS485 Standard allows a balanced transmission line to be shared in a party-line mode. As many as 32 driver/receiver pairs can share a two-wire party line network. Many characteristics of the drivers and receivers are the same as in the RS422 Standard. One difference is that the common mode voltage limit is extended and is +12V to -7V. Since any driver can be disconnected (or tristated) from the line, it must withstand this common mode voltage range while in the tristate condition. The following illustration shows a typical multidrop or party line network. Note that the transmission line is terminated on both ends of the line but not at drop points in the middle of the line. 21 Manual LPCI-COM422/8 Figure A-1: Typical RS485 Two-Wire Multidrop Network RS485 Four-Wire Multidrop Network An RS485 network can also be connected in a four-wire mode. In a four-wire network it's necessary that one node be a master node and all others be slaves. The network is connected so that the master communicates to all slaves and all slaves communicate only with the master. This has advantages in equipment that uses mixed protocol communications. Since the slave nodes never listen to another slave's response to the master, a slave node cannot reply incorrectly. 22 Manual LPCI-COM422/8 Customer Comments If you experience any problems with this manual or just want to give us some feedback, please email us at: tech@portwell.com. Please detail any errors you find and include your mailing address so that we can send you any manual updates. American Portwell Technology 44200 Christy Street, Fremont, CA 94538 Tel. (510)403-3399 FAX (510)403-3184 www.Portwell.com 23 Manual LPCI-COM422/8

Related Products

PORTWELL
Self powered DB9 RS-232 to DB9 RS-485 Serial Data Converter
PORTWELL
PORTWELL
Dual-port, asynchronous RS-422/485 serial communications card that can be i...
PORTWELL
Dual-port, asynchronous RS-232 serial communications card that can be insta...
PORTWELL
Quad-port, asynchronous RS-232 serial communications card that can be insta...
PORTWELL
Four-port, asynchronous RS-422 serial communications card designed for use...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.