PORTWELL LPCI-COM-4SM

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number LPCI-COM-4SM
Manufacturer PORTWELL
Category I/O Products
Price Request Quote
Lead Time Request Quote

Description

Low Profile Quad-port asynchronous RS-232/422/485 serial communication card that can be installed in any 3.3V or 5V PCI slot computer. Supports RS-232, RS-422 and RS-485 protocols with auto control for RS-485 under all OS at baud rates up to 921Kbps

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a LPCI-COM-4SM? We can help you find it at a competitive price!

Specifications

Categorization Information IO Products

Features

  • Eight-port Universal PCI serial communication card
  • Supports field selectable RS-232, RS-422 or RS-485 (2-wire and 4-wire) protocols
  • Includes type 16L788 octal UART with 64-Byte FIFO buffers in all modes
  • Speeds up to 921Kbps
  • Meets MD2 Low Profile PCI Bus Specification
  • Universal PCI, PCI-X, 3.3V and 5V compatible
  • Includes cable (no external breakout box required)
  • RS-232 only versions also available

Datasheet

Download "LPCI-COM-4SM.pdf" (461 KiB)

Extracted Text

MODEL LPCI-COM-8SM LPCI-COM-4SM LPCI-COM232-8 LPCI-COM232-4 USER MANUAL FILE: MLPCI-COM-8SM.B1f Manual LPCI-COM-8SM 2 Notice The information in this document is provided for reference only. Portwell does not assume any liability arising out of the application or use of the information or products described herein. This document may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of Portwell, nor the rights of others. IBM PC, PC/XT, and PC/AT are registered trademarks of the International Business Machines Corporation. Printed in USA. Copyright 2004, 2005 by Portwell I/O Products Inc. All rights reserved. WARNING!! ALWAYS CONNECT AND DISCONNECT YOUR FIELD CABLING WITH THE COMPUTER POWER OFF. ALWAYS TURN COMPUTER POWER OFF BEFORE INSTALLING A CARD. CONNECTING AND DISCONNECTING CABLES, OR INSTALLING CARDS INTO A SYSTEM WITH THE COMPUTER OR FIELD POWER ON MAY CAUSE DAMAGE TO THE I/O CARD AND WILL VOID ALL WARRANTIES, IMPLIED OR EXPRESSED. Manual LPCI-COM-8SM 3 Warranty Prior to shipment, Portwell equipment is thoroughly inspected and tested to applicable specifications. However, should equipment failure occur, Portwell assures its customers that prompt service and support will be available. All equipment originally manufactured by Portwell which is found to be defective will be repaired or replaced subject to the following considerations. Terms and Conditions If a unit is suspected of failure, contact Portwell' Customer Service department. Be prepared to give the unit model number, serial number, and a description of the failure symptom(s). We may suggest some simple tests to confirm the failure. We will assign a Return Material Authorization (RMA) number which must appear on the outer label of the return package. All units/components should be properly packed for handling and returned with freight prepaid to the Portwell designated Service Center, and will be returned to the customer's/user's site freight prepaid and invoiced. Coverage First Three Years: Returned unit/part will be repaired and/or replaced at Portwell option with no charge for labor or parts not excluded by warranty. Warranty commences with equipment shipment. Following Years: Throughout your equipment's lifetime, Portwell stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry. Equipment Not Manufactured by Portwell Equipment provided but not manufactured by Portwell is warranted and will be repaired according to the terms and conditions of the respective equipment manufacturer's warranty. General Under this Warranty, liability of Portwell is limited to replacing, repairing or issuing credit (at Portwell discretion) for any products which are proved to be defective during the warranty period. In no case is Portwell liable for consequential or special damage arriving from use or misuse of our product. The customer is responsible for all charges caused by modifications or additions to Portwell equipment not approved in writing by Portwell or, if in Portwell opinion the equipment has been subjected to abnormal use. "Abnormal use" for purposes of this warranty is defined as any use to which the equipment is exposed other than that use specified or intended as evidenced by purchase or sales representation. Other than the above, no other warranty, expressed or implied, shall apply to any and all such equipment furnished or sold by Portwell. Manual LPCI-COM-8SM 4 Table of Contents Chapter 1: Introduction................................................................................................. 6 Specifications ............................................................................................................ 8 Figure 1-1: Block Diagram (Only one serial channel shown) .................................. 9 Chapter 2: Installation................................................................................................. 10 Chapter 3: Option Selection ....................................................................................... 12 Figure 3-1: Simplified Termination Schematic....................................................... 12 Figure 3-2: Option Selection Map.......................................................................... 14 Chapter 4: Address Selection .................................................................................... 16 Chapter 5: Programming ............................................................................................ 17 Table 5-1: Baud Rate Divisor Values..................................................................... 18 Chapter 6: Connector Pin Assignments.................................................................... 19 Appendix A: Application Considerations.................................................................. 20 Table A-1: Connections Between Two RS422 Devices......................................... 20 Figure A-1: Typical RS485 Two-Wire Multidrop Network...................................... 22 Appendix B: HVDCI D-Connector Pinout Reference................................................ 23 Table B-1: HVDCI D-Connector Pin Assignments................................................. 23 Manual LPCI-COM-8SM 5 Chapter 1: Introduction This serial interface card was designed for effective multipoint transmission in any one of three modes on each channel. These modes are RS232, RS422 and RS485 (EIA485) protocol. The RS485 mode may be run in three manners. It may be run as a standard RTS controlled channel, an “Auto RTS (referred to by some as Auto RS485)” mode or as a “4 wire RS485 mode channel. The card is 6.60 inches long and may be installed in 3.3 or 5-volt PCI-bus slots of IBM PC or compatible computers. The card features eight independent, asynchronous serial ports, type 16788 buffered UARTs. This series of cards are available in 4-port and RS-232 only versions. RS422 Balanced Mode Operation The card supports RS422 communications and uses differential balanced drivers for long range and noise immunity. The card also has the capability to add load resistors to terminate the communications lines. RS422 communications requires that a transmitter supply a bias voltage to ensure a known "zero" state. Also, receiver inputs at each end of the network should be terminated to eliminate "ringing". The card supports biasing by default and supports termination by jumpers on the card. If your application requires the transmitter to be un-biased, please contact the factory. RS485 Balanced Mode Operation The card supports RS485 communications and uses differential balanced drivers for long range and noise immunity. RS485 operation involves switchable transceivers and the ability to support multiple devices on a single "party line". The RS485 specification defines a maximum of 32 devices on a single line. The number of devices served on a single line can be expanded by use of "repeaters". The card also has the capability to add load resistors to terminate the communications lines. RS485 communications requires that one transmitter supply a bias voltage to ensure a known "zero" state when all transmitters are off. Also, receiver inputs at each end of the network should be terminated to eliminate "ringing". The card supports biasing by default and supports termination by jumpers on the card. If your application requires the transmitter to be un-biased, please contact the factory. COM Port Compatibility Eight Type 16550 compatible UARTs incorporated within a single octal UART are used as Asynchronous Communication Elements (ACE). These include 64-byte transmit & receive buffers to protect against lost data in multitasking operating systems, while maintaining 100 percent compatibility with the original IBM serial port. The system assigns the address(es). A crystal oscillator is located on the card. This oscillator permits precise selection of baud rate up to 115,200 or, by changing a jumper, up to 921,600 with the standard crystal oscillator. The driver/receiver used, the SP841 in non-RS232 modes, is capable of driving extremely long communication lines at high baud rates. It can drive up to +60 mA on balanced lines and receive inputs as low as 200 mV differential signal superimposed on common mode noise of +12 V or -7 V. In case of communication conflict, the driver/receivers feature thermal shutdown. The driver/receiver used in RS232 mode is the SP211. Manual LPCI-COM-8SM 6 Communication Mode The card supports Half-Duplex communications with a 2-wire cable connection. Half-Duplex allows traffic to travel in both directions, but only one way at a time. RS485 communications commonly use the Half- Duplex mode since they share only a single pair of wires. Baud Rate Ranges The card has capability for two baud rate ranges and you can select which you wish to use for all ports on the card. One range is up to 115,200 baud and the other is up to 921,600 baud. Note Refer to Table 5-1, Baud Rate Divisor Values in chapter 5 of the manual. Auto-RTS Transceiver Control In RS485 communications, the driver must be enabled and disabled as needed, allowing all cards to share a two wire cable. The card controls the driver automatically. With automatic control, the driver is enabled when data is ready to be transmitted. With this card, the driver remains enabled for an adjustable period. It may be disabled at the completion of the transmission of the character (default), or can be set to wait up to one additional character's transmission time after data transfer is complete and then disabled. The receiver is, therefore, normally enabled, then disabled during RS485 transmissions, and then re- enabled after transmission is completed (adjustable from zero to plus one character transmission time). The card automatically adjusts it's timing to the baud rate of the data. (NOTE: Thanks to the automatic control feature, the card is ideal for use in Windows applications) Manual LPCI-COM-8SM 7 Specifications Communications Interface • I/O Connection: 68 Pin HVDCI SCSI style -Connector • Serial Ports: Eight cable terminated shielded male D-sub 9-pin connectors with standard IBM AT connectors compatible with RS485 specifications • Character length: 5, 6, 7, or 8 bits. • Parity: Even, odd or none. • Stop Interval: 1, 1.5, or 2 bits. • Serial Data Rates: Up to 115,200 baud, Asynchronous, A faster range of rates, up to 921,600, is achieved by jumper selection on the card. Type 16788 buffered UART. • Address: Continuously mappable within 0000 to FFFF (hex) range of PCI bus addresses. • Receiver Input Sensitivity: +200 mV, differential input. • Common Mode Rejection: +12V to -7V • Transmitter Output Drive Capability: 60 mA, with thermal shutdown. Environmental • Operating Temperature Range: 0 °C. to +60 °C. • Storage temperature Range: -50 °C. to +120 °C. • Humidity: 5% to 95%, non-condensing. • Power Required: +5VDC at 125 mA typical total power consumption. • Size: 6.6 inches long (167.6 mm) by 2.2 inches high (55.8 mm). Note The 16750 compatible UART uses 64-byte first-in-first-out buffers which are programmed through commands sent to the FIFO control register. Manual LPCI-COM-8SM 8 WITH AUTO-RTS CIRCUITRY Figure 1-1: Block Diagram (Only one serial channel shown) Manual LPCI-COM-8SM 9 PCI BUS VHDCI 68 PIN CONNECTOR Chapter 2: Installation A printed Quick-Start Guide (QSG) is packed with the card for your convenience. If you’ve already performed the steps from the QSG, you may find this chapter to be redundant and may skip forward to begin developing your application. The software provided with this card is on CD and must be installed onto your hard disk prior to use. To do this, perform the following steps as appropriate for your operating system. Configure Card Options via Jumper Selection Before installing the card into your computer, carefully read Chapter 3: Option Selection of this manual, then configure the card according to your requirements and protocol (RS-232, RS-422, RS-485, 4-wire 485, etc.). Our Windows based setup program can be used in conjunction with Chapter 3 to assist in configuring jumpers on the card, as well as provide additional descriptions for usage of the various card options (such as termination, bias, baud rate range, RS-232, RS-422, RS-485, etc.). CD Software Installation The following instructions assume the CD-ROM drive is drive “D”. Please substitute the appropriate drive letter for your system as necessary. DOS 1. Place the CD into your CD-ROM drive. 2. Type B- to change the active drive to the CD-ROM drive. 3. Type GLQR?JJ- to run the install program. 4. Follow the on-screen prompts to install the software for this board. WINDOWS 1. Place the CD into your CD-ROM drive. 2. The system should automatically run the install program. If the install program does not run promptly, click START | RUN and type BGLQR?JJ, click OK or press -. 3. Follow the on-screen prompts to install the software for this board. LINUX 1. Please refer to linux.htm on the CD-ROM for information on installing under linux. Note: COM boards can be installed in virtually any operating system. We do support installation in earlier versions of Windows, and are very likely to support future versions as well. Caution! * ESD A single static discharge can damage your card and cause premature failure! Please follow all reasonable precautions to prevent a static discharge such as grounding yourself by touching any grounded surface prior to touching the card. Manual LPCI-COM-8SM 10 Hardware Installation 1. Make sure to set switches and jumpers from either the Option Selection section of this manual or from the suggestions of SETUP.EXE. 2. Do not install card into the computer until the software has been fully installed. 3. Turn OFF computer power AND unplug AC power from the system. 4. Remove the computer cover. 5. Carefully install the card in an available 5V or 3.3V PCI expansion slot (you may need to remove a backplate first). 6. Inspect for proper fit of the card and tighten screws. Make sure that the card mounting bracket is properly screwed into place and that there is a positive chassis ground. 7. Install an I/O cable onto the card’s bracket mounted connector. 8. Replace the computer cover and turn ON the computer. Enter the CMOS setup program of your system and verify that the PCI plug-and-play option is set appropriately for your system. Systems running Windows 95/98/2000/XP/2003 (or any other PNP-compliant operating system) should set the CMOS option to OS. Systems running under DOS, Windows NT, Windows 3.1, or any other non-PNP-compliant operating system should set the PNP CMOS option to BIOS or Motherboard. Save the option and continue booting the system. 9. Most computers should auto-detect the card (depending on the operating system) and automatically finish installing the drivers. 10. Run PCIfind.exe to complete installing the card into the registry (for Windows only) and to determine the assigned resources. 11. Run one of the provided sample programs that was copied to the newly created card directory (from the CD) to test and validate your installation. The base address assigned by BIOS or the operating system can change each time new hardware is installed into or removed from the computer. Please recheck PCIFind or Device Manager if the hardware configuration is changed. Software you write can automatically determine the base address of the card using a variety of methods depending on the operating system. In DOS, the PCI\SOURCE directory shows the BIOS calls used to determine the address and IRQ assigned to installed PCI devices. In Windows, the Windows sample programs demonstrate querying the registry entries (created by PCIFind and NTIOPCI.SYS during boot-up) to determine this same information. Manual LPCI-COM-8SM 11 Chapter 3: Option Selection To help you locate the jumpers described in this section, refer to the Option Selection Map at the end of this section. Operation of the serial communications section is determined by jumper installation as described in the following paragraphs. For the convenience of the user, instructions for the placement of the jumpers is also silk screened on the back of the card. Terminations A transmission line should be terminated at the receiving end in its characteristic impedance. Installing a jumper at the locations labeled LDxO applies a 120Ω load across the transmit/receive input/output for RS485 operation. Jumpers having to do with the termination of each channel are located near the output connector. They are labeled by channel. The load jumper is labeled “LD”. The other two jumpers are used to connect the transmit and receive lines for the two wire RS485 mode. Tx+/Rx+ LD 120 0.01 F μ Tx-/Rx- Figure 3-1: Simplified Termination Schematic In RS485 operations where there are multiple terminals, only the RS485 ports at each end of the network should have terminating impedance as described above. To so terminate the COM A port, place a jumper at the location labeled Ch A -LD. To terminate the COM B, COM C, COM D, COM E, COM F and COM H ports, place jumpers at locations labeled Ch B - LD, Ch C - LD, Ch D - LD, Ch E - LD, Ch F - LD, Ch G - LD and Ch H - LD respectively. Also, for RS485 operation, there must be a bias on the TRX+ and TRX- lines. If the card is not to provide that bias, contact the factory technical support. Manual LPCI-COM-8SM 12 Data Cable Wiring RS-485 SignalPin Connection Ain/out+ 2 Ain/out- 3 100 Ω to Ground 5 Baud Rate Ranges The jumper labeled CLK X8 provides a means to select baud rates in a higher range. When a jumper is not placed on the out the CLK X8 position, the baud rate range is up to 115,200 baud. When it is in the CLK X8 position, the baud rate range is up to 921,600 baud. Interrupts Please note that, in WindowsNT, changes must be made to the system registry to support IRQ sharing. The following is excerpted from "Controlling Multiport Serial I/O Cards" provided by Microsoft in the MSDN library, documentid:mk:@ivt:nt40res/D15/S55FC.HTM, also available in the WindowsNT Resource Kit. The Microsoft serial driver can be used to control many dumb multiport serial cards. Dumb indicates that the control includes no on-board processor. Each port of a multiport card has a separate subkey under the HKLM\CurrentControlSet\Services\Serial subkey in the registry. In each of these subkeys, you must add values for DosDevices, Interrupt, InterruptStatus, PortAddress, and PortIndex because these are not detected by the Hardware Recognizer. (For descriptions and ranges for these values, see Regentry.hlp, the Registry help file on the WindowsNT Workstation Resource Kit CD.) For example, if you have an eight-port card configured to use address 0xFC00 with an interrupt of 05, the values in the Registry are: Serial2 subkey: Serial6 subkey: PortAddress = REG_DWORD 0xFC00 PortAddress = REG_DWORD 0xFC20 Interrupt = REG_DWORD 5 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM3 DosDevices = REG_SZ COM7 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 1 PortIndex = REG_DWORD 5 Indexed = REG_DWORD 0 Indexed = REG_DWORD 0 Serial3 subkey: Serial7 subkey: PortAddress = REG_DWORD 0xFC08 PortAddress = REG_DWORD 0xFC28 Interrupt = REG_DWORD 5 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM4 DosDevices = REG_SZ COM8 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 2 PortIndex = REG_DWORD 6 Indexed = REG_DWORD 0 Indexed = REG_DWORD 0 Serial4 subkey: Serial8 subkey: PortAddress = REG_DWORD 0xFC10 PortAddress = REG_DWORD 0xFC30 Interrupt = REG_DWORD 5 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM5 DosDevices = REG_SZ COM9 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 3 PortIndex = REG_DWORD 7 Indexed = REG_DWORD 0 Indexed = REG_DWORD 0 Serial5 subkey: Serial9 subkey: PortAddress = REG_DWORD 0xFC18 PortAddress = REG_DWORD 0xFC38 Interrupt = REG_DWORD 5 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM6 DosDevices = REG_SZ COM10 InterruptStatus = REG_DWORD 0xFC40 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 4 PortIndex = REG_DWORD 8 Indexed = REG_DWORD 0 Indexed = REG_DWORD 0 Manual LPCI-COM-8SM 13 6.60" H G F PORT CONFIG BAUD x8 E PORT H D CONFIG D G C C F B B A E A Figure 3-2: Option Selection Map The card has 8 separate channels which can be individually configured. Each channel can be used in: 1) RS485 (2 wire mode) - This mode may use “Auto RTS” 2) RS422 3) RS232 4) RS485 (4 wire mode) The jumpers on the card must be properly placed in order to have the card function properly. In order to select the basic mode for a channel, the M1 and M2 jumpers be properly placed. (These jumpers are located at the end of the card away from the cable connector). Mode M1 M2 RS485 (2 Wire Mode) IN OUT RS485 (4 Wire Mode) OUT IN RS422 IN IN RS232 OUTOUT Manual LPCI-COM-8SM 14 2.20" Other jumpers: 1) RS 485 (2 wire mode) - Two jumpers must be installed for each channel in this mode in order to connect the output and input lines. These jumpers are located near the cable connector and are labeled with the channel letter and “485.” 2) RS 485 (2 wire mode) using “Auto RTS” - One jumper must be installed for each channel in this mode. This jumper is located at the end of the card away from the cable connector, adjacent to the “M” jumpers and are labeled with the channel letter and “A8". 3) RS 485 or RS 422 Loads - One jumper must be installed for each channel which requires a load. This jumper is located at the cable connector end of the card and is labeled with the channel letter and “LD.” Notes: 1) Any unneeded jumpers that are installed can cause the card to function incorrectly. 2) If the “Auto RTS” jumpers are changed, the card should be rebooted or reset. This is required because the status of the jumpers is read when the card is reset and is used to program the Auto RTS function into the appropriate channel(s) of the UART. If the state of this jumper is changed, the UART will not be properly programmed until the jumper has been reread. To do this, the card must be reset. Manual LPCI-COM-8SM 15 Chapter 4: Address Selection The card uses one address space. COM A, COM B, COM C, COM D, COM E, COM F, COM G and COM H each occupy eight consecutive register locations. The interrupt register which indicates which port or ports caused the interrupt is located at base address + 64. PCI architecture is Plug-and-Play. This means that the BIOS or Operating System determines the resources assigned to PCI cards rather than you selecting those resources with switches or jumpers. As a result, you cannot set or change the card's base address. You can only determine what the system has assigned. To determine the base address that has been assigned, run the PCIFind.EXE utility program provided. This utility will display a list of all of the cards detected on the PCI bus, the addresses assigned to each function on each of the cards, and the respective IRQs (if any) allotted. Alternatively, some operating systems (Windows 95/98/2000/XP) can be queried to determine which resources were assigned. In these operating systems, you can use the Device Manager utility from the System Applet of the control panel. The card is installed in the Data Acquisition class of the Device Manager list. Selecting the card, clicking Properties, and then selecting the Resources Tab will display a list of the resources allocated to the card. The PCI bus supports 64K of I/O space. Your card's addresses may be located anywhere in the 0000 to FFFF hex range. PCIFind uses the Vendor ID and Device ID to search for your card, then reads the base address and IRQ. If you want to determine the base address and IRQ yourself, use the following information. The Vendor ID for the card is 494F. (ASCII for "IO") The Device ID for the card is 10E8h. Manual LPCI-COM-8SM 16 Chapter 5: Programming Sample Programs There are sample programs provided with the card in C, Pascal, QuickBASIC, and several Windows languages. DOS samples are located in the DOS directory and Windows samples are located in the WIN32 directory. Windows Programming The card installs into Windows as COM ports. Thus the Windows standard API functions can be used. In particular: ►CreateFile() and CloseHandle() for opening and closing a port. ►SetupComm(), SetCommTimeouts(), GetCommState(), and SetCommState() to set and change a port’s settings. ►ReadFile() and WriteFile() for accessing a port. See the documentation for your chosen language for details. Under DOS, the process is identical to programming any 16550- or 16750-compatible UART. Manual LPCI-COM-8SM 17 Address Map The core of the UART function is supplied by the EXAR XR16L788 chip. This chip is 16550 and 16750 compatible, but has extra features that require communicating with an additional 8 registers per channel. For instance, it is necessary to set the “Auto RTS” function. (EXAR refers to this function as “Auto RS485" in their literature). The required writing to the UART is done automatically when the card is rebooted. In order to utilize standard software that communicates only with the first 8 registers of each channel, addresses are remapped on the card. The 8 UARTS occupy the first 64 addresses. The interrupt status register is located at base + 40h. Baud Rates On the card, the UART clock frequency is 1.8432 MHz. Below is a table of popular divisor frequencies. Baud Rate Divisor x1 Divisor x8 Max Diff. Cable Length* 921600 - 1 250 ft 460800 - 2 550 ft 230400 - 4 1400 ft 153600 - 6 2500 ft 115200 1 8 3000 ft 57600 2 16 4000 ft 38400 3 24 4000 ft 28800 4 32 4000 ft 19200 6 48 4000 ft 14400 8 64 4000 ft 9600 12 96 – Most Common 4000 ft 4800 24 192 4000 ft 2400 48 384 4000 ft 1200 96 768 4000 ft *These are theoretical maximums based on typical conditions and good quality cables, based on the EIA 485 and EIA 422 standard for balanced differential drivers. Table 5-1: Baud Rate Divisor Values Manual LPCI-COM-8SM 18 Chapter 6: Connector Pin Assignments Input/Output Connections The card’s Serial Communications card uses eight individual 9-pin connectors, provided via a spider cable from a 68-pin HVDCI D-connector. To ensure that there is minimum susceptibility to EMI and minimum radiation, it is important that the card mounting bracket be properly screwed into place and that there be a positive chassis ground. Also, proper EMI cabling techniques (cable connect to chassis ground at the aperture, shielded twisted-pair wiring, etc) be used for the input/output wiring. DB-9 Male Pin for each of Ch A-G RS-232 Signals RS-485 Signals RS-422 Signals (Industry Standard) (2 Wire) (Also 4wire RS485) 1 Ch x - 1 DCD RX-/TX- RX- 1 Ch x - 2 RX TX+/RX+ TX+ 1 Ch x - 3 TX TX-/RX- TX- Ch x - 4 DTR Ch x - 5 Gnd Gnd Gnd Ch x - 6 DSR Ch x - 7 RTS Ch x - 8 CTS 1 Ch x - 9 RI RX+/TX+ RX+ Table 6-1: Connector Pin Assignments 1 RS485 (2 wire) requires the installation of jumpers on the card to properly connect these pins. When using the spider cable, the appropriate DB 9 connectors will have pin 1 connected to pin 3 and pin 2 is connected to pin 9. Manual LPCI-COM-8SM 19 Appendix A: Application Considerations Introduction Working with RS422 and RS485 devices is not much different from working with standard RS232 serial devices and these two standards overcome deficiencies in the RS232 standard. First, the cable length between two RS232 devices must be short; less than 50 feet at 9600 baud. Second, many RS232 errors are the result of noise induced on the cables. The RS422 standard permits cable lengths up to 5000 feet and, because it operates in the differential mode, it is more immune to induced noise. Connections between two RS422 devices (with CTS ignored) should be as follows: Device #1 Device #2 Signal Pin No.Signal Pin No. Gnd 5 Gnd 5 + + TX 2 RX 9 - - TX 3 RX 1 + + RX 9 TX 2 - - RX 1 TX 3 Table A-1: Connections Between Two RS422 Devices A third deficiency of RS232 is that more than two devices cannot share the same cable. This is also true for RS422 but RS485 offers all the benefits of RS422 plus allows up to 32 devices to share the same twisted pairs. An exception to the foregoing is that multiple RS422 devices can share a single cable if only one will talk and the others will all receive. Balanced Differential Signals The reason that RS422 and RS485 devices can drive longer lines with more noise immunity than RS232 devices is that a balanced differential drive method is used. In a balanced differential system, the voltage produced by the driver appears across a pair of wires. A balanced line driver will produce a differential voltage from +2 to +6 volts across its output terminals. A balanced line driver can also have an input "enable" signal that connects the driver to its output terminals. If the "enable signal is OFF, the driver is disconnected from the transmission line. This disconnected or disabled condition is usually referred to as the "tristate" condition and represents a high impedance. RS485 drivers must have this control capability. RS422 drivers may have this control but it is not always required. A balanced differential line receiver senses the voltage state of the transmission line across the two signal input lines. If the differential input voltage is greater than +200 mV, the receiver will provide a specific logic state on its output. If the differential voltage input is less than -200 mV, the receiver will provide the opposite logic state on its output. A maximum operating voltage range is from +6V to -6V allows for voltage attenuation that can occur on long transmission cables. A maximum common mode voltage rating of +7V provides good noise immunity from voltages induced on the twisted pair lines. The signal ground line connection is necessary in order to keep the common mode voltage within that range. The circuit may operate without the ground connection but may not be reliable. Manual LPCI-COM-8SM 20 Parameter Conditions Min. Max. Driver Output Voltage (unloaded) 4V 6V -4V -6V Driver Output Voltage (loaded) LD and LDGND 2V jumpers in -2V Driver Output Resistance 50Ω Driver Output Short-Circuit Current +150 mA Driver Output Rise Time 10% unit interval Receiver Sensitivity +200 mV Receiver Common Mode Voltage Range +7V Receiver Input Resistance 4KΩ Table A-2: RS422 Specification Summary To prevent signal reflections in the cable and to improve noise rejection in both the RS422 and RS485 mode, the receiver end of the cable should be terminated with a resistance equal to the characteristic impedance of the cable. (An exception to this is the case where the line is driven by an RS422 driver that is never "tristated" or disconnected from the line. In this case, the driver provides a low internal impedance that terminates the line at that end.) Note You do not have to add a terminator resistor to your cables when you use the card. Termination resistors for the RX+ and RX- lines are provided on the card and are placed in the circuit when you install the Ch X - LD jumpers. (See the Option Selection section of this manual.) Manual LPCI-COM-8SM 21 RS485 Data Transmission The RS485 Standard allows a balanced transmission line to be shared in a party-line mode. As many as 32 driver/receiver pairs can share a two-wire party line network. Many characteristics of the drivers and receivers are the same as in the RS422 Standard. One difference is that the common mode voltage limit is extended and is +12V to -7V. Since any driver can be disconnected (or tristated) from the line, it must withstand this common mode voltage range while in the tristate condition. The following illustration shows a typical multidrop or party line network. Note that the transmission line is terminated on both ends of the line but not at drop points in the middle of the line. Figure A-1: Typical RS485 Two-Wire Multidrop Network RS485 Four-Wire Multidrop Network An RS485 network can also be connected in a four-wire mode. In a four-wire network it's necessary that one node be a master node and all others be slaves. The network is connected so that the master communicates to all slaves and all slaves communicate only with the master. This has advantages in equipment that uses mixed protocol communications. Since the slave nodes never listen to another slave's response to the master, a slave node cannot reply incorrectly. Manual LPCI-COM-8SM 22 Appendix B: HVDCI D-Connector Pinout Reference Connections will normally be made to the 9-pin connectors through the breakout cable. In case you wish to connect directly to the 68-pin connector, the pins translate as follows. DB-9 Ch A Ch B Ch C Ch D Ch E Ch F Ch G Ch H Pins Pins on Pins on Pins on Pins on Pins on Pins on on 68-Pin Pin pins on 68-Pin 68-Pin 68-Pin 68-Pin 68-Pin 68-Pin 68-pin 1 37 41 45 49 53 57 61 65 2 1 5 9 13 17 21 25 29 3 2 6 10 14 18 22 26 30 4 3 7 11 15 19 23 27 31 1 1 1 1 2 2 2 2 5 33 33 33 33 67 67 67 67 6 38 42 46 50 54 58 62 66 7 35 39 43 47 51 55 59 63 8 36 40 44 48 52 56 60 64 9 4 8 12 16 20 24 28 32 Table B-1: HVDCI D-Connector Pin Assignments Pins 34 and 68 on the 68-pin HVDCI D-Connector provide +5Volts DC Fused, but are not available on any of the DB-9 connectors. 1 Pin 33 on the 68-Pin connector is Ground, common to Pin 5 on each of the DB-9 connectors associated with COM Channels A, B, C, and D. 2 Pin 67 on the 68-Pin connector is Ground, common to Pin 5 on each of the DB-9 connectors associated with COM Channels A, B, C, and D. Manual LPCI-COM-8SM 23 Customer Comments If you experience any problems with this manual or just want to give us some feedback, please email us at: tech@portwell.com. Please detail any errors you find and include your mailing address so that we can send you any manual updates. Manual LPCI-COM-8SM 24

Related Products

PORTWELL
Self powered DB9 RS-232 to DB9 RS-485 Serial Data Converter
PORTWELL
Low Profile Quad-port asynchronous RS-232serial communication card that can...
PORTWELL
Low Profile Eight-port asynchronous RS-232 serial communication card that c...
PORTWELL
Low Profile Eight-port asynchronous RS-232/422/485 serial communication car...
PORTWELL
Dual-port, asynchronous RS-232 serial communications card that can be insta...
PORTWELL
Dual-port, asynchronous RS-232/422/485 serial communications card that can...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.156 seconds.