PIXUS SUBRACKS, 2U-9U, 19"

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number SUBRACKS, 2U-9U, 19"
Manufacturer PIXUS
Category Uncategorized
Price Request Quote
Lead Time Request Quote

Description

The modular Eurocard concept of Kaparel/Rittal subracks permits a wide range of applications with the minimum number of components, since all Ripac subracks are based on the same horizontal rails and system components. The only difference lies in the design of the side panels and configuration variants. Equipped with a backplane and power supply, a standard subrack can be rapidly upgraded to an MPS system, for example. The subracks are shock and vibration-tested and conform to IEC 60 297-3, 60 297-4, 60 297-5-103 and IEEE 1101.1 and 1101.10

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a SUBRACKS, 2U-9U, 19" ? We can help you find it at a competitive price!

Specifications

Size 2U-9U, 19" - 21HP wide

Features

  • Modular extruded aluminum design
  • For housing custom backplanes and motherboards with front (and/or rear) pluggable modules. (If standard architecture backplane is required, please see our Enclosures/Systems section.)
  • Standard, EMC, Mobile (Industrial Rugged), and Compact designs.
  • 2U-4U horizontal-mount subracks
  • 3U, 4U, 6U, 7U, and 9U vertical-mount subracks (for 3U and 6U modules or custom sizes)
  • Versatile card guide mounting for various pitch modules (plastic and aluminum card guides available)
  • Rear I/O access optional
  • Optional PSU and fan implementations

Datasheet

Download "Subracks-datasheet-d3.pdf" (1484 KiB)

Extracted Text

Subracks, 2U-9U, 19” - 21HP wide Subracks, Enclosure Frames KEY FEATURES INDUSTRIES  Modular extruded aluminum design.  Energy  For housing custom backplanes and mother-  Communications boards with front (and/or rear) pluggable mod-  Industrial ules. (If standard architecture backplane is  Medical required, please see our Enclosures/Systems  Military/Aerospace section.)  Railway/Transportation  Standard, EMC, Mobile (Industrial Rugged),  Test & Measurement and Compact designs.  2U-4U horizontal-mount subracks.  3U, 4U, 6U, 7U, and 9U vertical-mount With German engineering and low-cost Asian and European subracks (for 3U and 6U modules or custom manufacturing, Pixus offers superior quality and design versatil- sizes) ity within a cost-effective solution. Whether you need a simple  Versatile card guide mounting for various pitch subrack or a full enclosure with shielding, fan and power options, modules (plastic and aluminum card guides Pixus’ modular designs offer a solution for you. available).  Rear I/O access optional. Pixus Technologies can modify this product to meet special cus-  Optional PSU and fan implementations. tomer requirements without NRE (minimum order placement is required). Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Subrack, standard and EMC — 3U, 6U  Standard or EMC shielded enclosures  3U and 6U heights standard  EMC covers for shielding, additional gasket- ing options are available  19” width and 220mm, 280mm, 340mm, and 400mm depths. Standard type also available in 160mm.  Vibration and shock tested to DIN IEC 68-2- 6 test Fc and DIN IEC 68-2-27 test Ea EMC subracks with perforated top and bottom covers for shielding. Stan- dard 19” rackmount and various widths and depths available upon request. Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Subrack, standard and EMC — 4U, 7U, 9U  Standard or EMC shielded enclosures  3U and 6U heights standard  EMC covers for shielding, additional gas- keting options are available  19” width and 220mm, 280mm, 340mm, and 400mm depths. Standard type also available in 160mm.  Vibration and shock tested to DIN IEC 68 -2-6 test Fc and DIN IEC 68-2-27 test Ea EMC subracks with perforated top and bottom covers for shielding. For plugging of standard 3U, 6U or custom sized modules. Additional 1U to 3U spacing to allow for fan/cooling implementation. Standard 19” rack- mount and various widths and depths available upon request. Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Mobile Subrack — 3U and 6U  For mobile or rugged industrial applica- tions  3U and 6U heights standard  19” width and 245mm depth  Reinforced, thick extrusions for additional weight, shock, and vibration.  Vibration and shock tested to DIN IEC 68 -2-6 test Fc and DIN IEC 68-2-27 test Ea  2.5mm aluminum sheet side panels  Clear chromate finish  Designed to DIN 41 494, IEC 60 and IEEE specifications Rugged subracks with thicker reinforced extrusions designed initially for German railway. Can be used in various rugged, mobile, and transporta- tion applications. Standard 19” rackmount and various widths and depths The Mobile Subracks have been tested for use in the German national railway. The test was conducted in accordance to EN 50 155 (electronic equipment for rail vehicles). The configuration of the tested subracks conforms to IEC 61587- 1. Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Compact Subrack — 3U and 6U  Compact subracks in 21HP and 42HP widths  3U and 6U heights standard  225mm and 295mm depths  EMC and non-EMC versions  Vibration and shock tested to DIN IEC 68 -2-6 test Fc and DIN IEC 68-2-27 test Ea  2.5mm aluminum sheet side panels  Clear chromate finish  Designed to DIN 41 494, IEC 60 and IEEE specifications Smaller subracks in 21HP and 42HP sizes. Adapters available for simple rail or plate mounting. Various heights, widths and depths available upon request. Special adapter options allow simple rail installation. Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Standard Rails—Subrack with Backplane Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Subrack Components Side panels Z-rail Threaded insert EMC gasket strip Conductive backplane strip Divider kit example—6U divided to 3U (Click on any of the photos to link to that section on the Web site) Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Ordering Options BXX-THHW-DR-CBSC-FWP B = Backplane Type CompactPCI, cPCIe -- see CompactPCI Chassis section on Web AdvancedTCA -- see AdvancedTCA Chassis section on Web VME, VPX, VXS -- see VME/VPX Chassis section on Web MicroTCA -- see MicroTCA Chassis section on Web No backplane -- See Instrument Cases section on Web or call factory Power backplane = A 3U Custom backplane = B 6U Custom backplane = C Other size Custom backplane = D XX = Backplane Slots 01-21 = ("01" = 1 slot, "21" = 21 slots) T = Type Standard (19" rackmount) = 1 EMC (19" rackmount) =2 Mobile (19" rackmount -- rugged industrial, railway) =3 Compact = 4 (21HP or 42HP widths only) MIL Rugged -- see Rugged enclosures section vertical mount HH = Height 3U = 3C 4U (for plugging 3U boards plus 1U for fan tray) = 4C 6U = 6C 7U (for plugging 3U boards plus 1U for fan tray) = 7C 9U = 9C horizontal mount 2U = 2H 3U = 3H 4U = 4H (Horizontal mount plugs 6U boards with provisions for (2x) 3U) 21HP = A (Compact Enclosure Type only) W = Width 42HP= B 84HP (19") = C (19" [84HP] models automatically include rack mounting flanges) Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Ordering Options BXX-THHW-DR-CBSC-FWP D = Depth—Front pluggable module 160mm = 6 (Standard, Compact) 220mm = 2 (Standard, EMC, Mobile, Compact) 280mm = 8 (Standard, EMC) 340mm = 4 (Standard, EMC) 400mm = 0 (Standard, EMC) (enclosure total depth typically 25-65mm beyond max module lengths above) R = Rear I/O Access 80mm = A 160mm = B Other depth = C Not required = X (Rear I/O includes card guides and mounting for pluggable modules) C = Top Cover vented top cover = A non-vented top cover = B no cover = X B = Bottom Cover vented top cover = Y non-vented top cover = Z no cover = X S = Backplane Insulating/ Conductive strips Insulated strip = I Conductive strip = C None = X C = Front carry handles (subrack) Yes = Y No = X Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com Subracks, 2U-9U, 19” - 21HP wide Ordering Options BXX-THHW-DR-CBSC-FWP F = Standard Fan Tray Yes = Y No = X If Yes, contact Pixus to specify requirement W = Power Supply Yes = Y No = X If Yes, contact Pixus to specify requirement P = Panels — Front/Rear, Board or Filler Yes = Y No = X If Yes, contact Pixus to specify requirement Example Configuration For a 6U Custom Backplane, 12 slots, EMC Subrack, 6U Height, 84HP width, 280mm depth, no I/O required, vented top and bottom covers, insulated strip, carry handles, fan tray, power supply, and filler panels = part number C12-26CC-8X-AYIY-YYY FAQs/Support For configuration questions, visit the Pixus FAQs/Help page. Pixus Technologies Inc USA (916) 524-8242 Canada (519) 885-5775 Email: sales@pixustechnologies.com Website: www.pixustechnologies.com

Related Products

PIXUS
The Kaparel/Rittal 23000 Series of 3U PXI backplanes are PXI R2.0 and nPICM...
PIXUS
Due to its compact design, the 5 U shelf version offers optimum application...
PIXUS
The 13U ATCA shelf design has over 15,000 global installs. This superior ch...
PIXUS
The ATR012 is a MIL-rugged ATR enclosure, with ARINC 404 versions available...
PIXUS
The ATR034T is a MIL-rugged ATR enclosure, with ARINC 404 versions availabl...
PIXUS
Configuration of 482.6 mm (19") industrial computer systems to VME specific...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2021 GID Industrial, All Rights Reserved.
Page generated in 0.031 seconds.