Part Number | BB-FOSTCDRI-PH-SC |
---|---|
Manufacturer | ADVANTECH |
Category | Serial Converters, Repeaters and Suppressors » Serial Converters |
Price | Request Quote |
Lead Time | Request Quote |
The BB-FOSTCDRI-PH-SC series are premium heavy industrial serial to fiber optic converters. Designed for rugged industrial environments, they have been put through most exacting compliance testing in the industry. Meeting IEC 61850-3 and IEEE 1613 requirements, they are suitable for installation in electrical substations. These specifications are more stringent than NEMA TS1/TS2 requirements for transportation applications. Powerful isolation protects equipment and data from damaging ground loops and surges. Additional isolation on the power supply circuits adds a third degree of protection.
Packaged in a rugged IP30 metal case, these units convert serial signals to multi-mode or single-mode fiber optic. Bit-wise enabled circuitry automatically detects the data rate without setting a DIP switch.
In addition to direct point-to-point connectivity, operation in multi-drop mode is possible enabling serial devices to communicate with up to 31 others in a fiber ring. Supporting mixed standards, you can replace other converters and add EMI/RFI protection inherent to fiber optic communications.
Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.
Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.
Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.
Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.
Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.
Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.
After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.
IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.
Do you need a BB-FOSTCDRI-PH-SC? We can help you find it at a competitive price!
General Connector | Plug-in 5P/15P screw terminal blocks |
---|---|
General Communication Speed | Serial: From 9.6 to 115.2 kbps |
General Interface | Fiber Optic to RS-232/422/485 |
General Isolation Protection | 2000 VDC |
General Temperature (Storage) | -40~85°C (40~185 °F) |
General Humidity | 0 ~ 95%, non-condensing |
General Temperature (Operating) | -40~85°C (40~185 °F) |
Display LED Indicators | Communication and Power |
Power Supply Power Requirement | 10~48 VDC |
Categorization Information | Intelligent Connectivity Industrial Communication Serial Converters, Repeaters and Suppressors Serial Converters |
Download "c80d6011-48b9-4c61-9bcb-f41ccf406a6f.pdf" (513 KiB)
Heavy Industrial Serial to Fiber Optic Converters Models FOSTCDRI-PH-MC, FOSTCDRI-PH-MT, FOSTCDRI-PH-SC www.advantech-bb.com PRODUCT FEATURES • IEEE-61850-3 • IEEE 1613 • NEMA TS2 (FOSTCDRI-PH-MT) • Multi- or Single-Mode, ST or SC Versions • -40 to 85°C Wide Operating Temperature • Rugged, IP30 Metal Panel Mount Case • 50G Shock, 4G Vibration • 2kV Triple Isolation The FOSTCDRI-PH-xx series are premium heavy industrial serial to fiber optic ORDERING INFORMATION converters. Designed for rugged industrial environments, they have been put MODEL NUMBER DESCRIPTION through most exacting compliance testing in the industry. Meeting IEC 61850- FOSTCDRI-PH-MC Serial to Multi-mode SC Converter 3 and IEEE 1613 requirements, they are suitable for installation in electrical FOSTCDRI-PH-MT Serial to Multi-mode ST Converter substations. These specifications are more stringent than the NEMA TS1/ FOSTCDRI-PH-SC Serial to Single-mode SC Converter TS2 requirements for transportation applications. Powerful isolation protects equipment and data from damaging ground loops and surges. Additional isolation on the power supply circuits adds a third degree of protection. Packaged in a rugged IP30 metal case, these converters convert serial signals ACCESSORIES to multi-mode or single-mode fiber optic. Bit-wise enabled circuitry automatically MDR-20-24 - DIN Rail Mount Power Supply 24VDC, 1.0 A output power detects the data rate without setting a DIP switch. DRAD35 - DIN Rail Mounting Kit 35mm In addition to direct point-to-point connectivity, operation in multi-drop mode is possible. This enables serial devices to communicate with up to 31 others in a fiber ring. Supporting mixed standards, you can replace other converters and add the EMI / RFI protection inherent to fiber optic communications. MECHANICAL All product specifications are subject to change without notice. FOSTCDRI-PH-MC, FOSTCDRI-PH-MT, FOSTCDRI-PH-SC_3017ds orders@advantech-bb.com Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104 support@advantech-bb.com European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445 Heavy Industrial Serial to Fiber Optic Converters Models FOSTCDRI-PH-MC, FOSTCDRI-PH-MT, FOSTCDRI-PH-SC SPECIFICATIONS SERIAL TECHNOLOGY TERMINAL BLOCKS RS-232 TD, RD, GND Wire Size Accepted 28 to 12 AWG, copper wire only RS-422 TDA(-), TDB(+), RDA(-), RDB(+) Pitch 5.08 mm RS-485 4-Wire TDA(-), TDB(+), RDA(-), RDB(+) Insulation Resistance ≥500 MΩ @ 500 VDC RS-485 2-Wire Data A(-), Data B(+) Maximum Torque 5 Kg / cm Serial Connector 5-position, removable terminal block INDICATORS Data Rate 9.6 to 115.2 Kbps Power Red LED Isolation 2 KV RMS, 1 minute TD / RD (Each Port) Green LED 600 W peak power dissipation MECHANICAL Surge Protection Clamping time < 1 pico-second Dimensions 13.24 x 9.29 x 3.0 cm (5.2 x 3.7 x 1.3 in) Industrial Bus Modbus ASCII / RTU Enclosure IP30 metal, panel mount Bias Built-in, switchable 1.2KΩ XMT/RCV Weight 0.46 lbs (208.65 grams) Termination Built-in, switchable 120Ω MTBF 127,103 hours FIBER OPTIC TECHNOLOGY MTBF Calc. Method Parts Count Reliability Prediction Type / Wavelength Multi-mode or Single-mode 1310 nM ENVIRONMENTAL Output Power (MM) -19 (min), -14 (max) dBm Operating Temperature -40 to 85 °C (-40 to 176 °F) Output Power (SM) -15 (min), -8 (max) dBm Storage Temperature -40 to 85 °C (-40 to 176 °F) RCV Sensitivity ≤ -32 dBm Operating Humidity 0 to 95% Non-condensing Cable 62.5 / 125 µM (MM), 9 / 125µM (SM) REGULATORY Data Rate 9.6 to 115.2 kbps FCC, CE, IEC 61850-3, IEEE 1613 Multi-mode: 2 kM (1.25 mi) UL C1 D2, File: E245458 Distance Approvals Single-mode: 15 kM (9.3 mi) Fiber Light Modulated NEMA TS2 (Model FOSTCDRI-PH-MT) POWER Source External Power Connector 2-position, removable terminal block Input Voltage 10 to 48 VDC (56 VDC maximum) Power Consumption 0.9 W typical (2.6W with termination) IEC 61850-3 ELECTRO MAGNETIC INTERFERENCE SPECIFICATIONS Test Description Test Level Level Enclosure Contact 8 kV 4 61000-4-2 ESD Enclosure Air 15 kV 4 61000-4-3 Radiated RFI Enclosure Ports 10 V/m 3 Signal Ports 4 kV @ 2.5 Khz - 61000-4-4 Burst (Fast Transient) DC Power Ports 4 kV 4 DRAWING/ARTWORK? Signal Ports 2 kV line to earth, 1 kV line to line 4 61000-4-5 Surge DC Power Ports 2 kV line to earth, 1 kV line to line 3 Signal Ports 10 V RMS 3 61000-4-6 Induced (Conductive) RFI DC Power Ports 10 V RMS 3 Signal Ports 2.5 kV common, 1 kV diff mode @ 1MHz 3 61000-4-12 Damped Oscillatory DC Power Ports 2.5 kV common, 1 kV diff mode @ 1MHz 3 Signal Ports 30 V Continuous, 300 V for 1 s 4 61000-4-16 Mains Frequency Voltage DC Power Ports 30 V Continuous, 300 V for 1 s 4 61000-4-17 Ripple on DC Power Supply DC Power Ports 10% 3 IEEE 1613 C37.90 ELECTROMAGNETIC INTERFERENCE SPECIFICATIONS Enclosure Contact 8 kV C37.90.3 ESD - Enclosure Air 15 kV C37.90.2 Radiated RFI Enclosure Ports 10 v/m - Signal Ports 4 kV @ 2.5 kHz C37.90.1 Fast Transient - DC Power Ports 4 kV ENVIRONMENTAL SPECIFICATIONS 60068-2-1 Cold Temperature Test Ad -40 °C, 16 Hours - 60068-2-2 Dry Heat Test Bd +85 °C, 16 Hours - 60068-2-30 Humidity (damp heat cycle) Test Dd 90% (non-condensing) +55 °C, 6 Cycles - IEC 600068-2-6 Vibration Test Fc 4g Class 2 IEC 600068-2-27 Shock Test Ea 50g Class 2 IEC 60068-2-32 Drop - 6 faces, 3 edges, 1 corner, total 10 drops at 1 m - orders@advantech-bb.com Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104 support@advantech-bb.com European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.
GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.
All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.