Details

Part Number 4683-TTM-2F
Manufacturer ACROMAG
Category Network Repeaters »  RS-485 Repeaters
Price Request Quote
Lead Time Request Quote

Description

RS485 Network Repeater
Acromag's RS-485 network repeater device allows users to take full advantage of the RS-485 standard's extended communication distances and multi-dropping capabilities. In addition, these devices offer field selectable End-of-Line Network (EOLN) terminations on both the A and B networks.Operation is transparent to all devices and no handshaking is required. Up to thirty-two RS-485 devices can be driven. Network repeaters are ready to mount on any base plate. Or, for a harsh environment, it can be installed in a NEMA enclosure of your choice. No enclosure is necessary for use in a laboratory or office. Installation requires mounting, connecting power and cables, and setting the baud rate.RS485-to-RS485 Repeater, 115V AC powerRS485-to-RS485 Repeater, 230V AC power

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 4683-TTM-2F? We can help you find it at a competitive price!

Specifications

Categorization Information Ethernet, Modbus & Profibus I/O
Network Repeaters
RS-485 Repeater
4683 Series

Features

  • Designed for use with Johnson Controls N2 or BACnet MS/TP bus
  • 115V AC ±10%, 50/60 Hz, 0.05A or 230V AC ±10%, 50/60 Hz, 0.03A or 24V AC ±10%, 50/60 Hz, 0.18A typical power
  • Operating temperature: -25 to 70° C (-13 to 158° F)
  • Designed for use with Johnson Controls N2 or BACnet bus.
  • I/O signal isolation. No handshaking. No extra control lines.
  • Baud rates of 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K, and 76.8K are switch selectable.
  • Field-selectable end-of-line network terminations on both A and B sides.
  • Electrical transient protection is provided. This protects the host computer from destructive noise spikes and other transient signals.
  • Status LED's indicate transmission direction, RS-485 bus fault conditions, and power applied.
  • 115V, 230V, and 24V AC power models available.

Datasheet

Download "4683-TTM%20RS-485%20to%20RS-485%20Network%20Repeater.pdf" (501 KiB)

Extracted Text

Network Accessories: 4683 Series 4683-TTM RS-485 to RS-485 Network Repeater GROUND NETWORK CONNECTIONS AC (LO) D D COM D D COM AC (HI) 4683-TTM-3F (24VAC) HOT COM G RS-485 RS-485 4683-TTM-2F (230VAC) L1 L2 G SIDE A SIDE B 4683-TTM-1F (115VAC) L1 W G AC Input TB2 TB1 TB3 12345678 1 - 600 5 - 9600 O BAUD 2 - 1200 6 - 19.2K N RATE 3 - 2400 7 - 38.4K FAULT TX TX FAULT PWR 4 - 4800 8 - 76.8K A S1 B - A A - B B Status Baud Rate Status LEDs Switches LEDs For N2 or BACnet MS/TP bus ◆ Drives up to 32 RS-485 devices ◆ Isolates and boosts signal up to 4000 ft. Description Key Features & Benefits Operation ■ Designed for use with Johnson Controls Model 4683-TTM-xF network repeaters Models N2 or BACnet bus isolate and boost RS-485 signals allowing 4683-TTM-1F: 115V AC Power communication signals to travel another 4000 ft. 4683-TTM-2F: 230V AC Power ■ No handshaking Each repeater permits the addition of another 32 4683-TTM-3F: 24V AC Power ■ No extra control lines unit load to a network. Acromag’s RS-485 network repeater device ■ I/O signal isolation The repeater has two RS-485 “sides” known as allows users to take full advantage of the RS-485 the A and B sides. The A side standard’s extended communication distances ■ Baud rates of 600, 1200, 2400, 4800, 9600, typically connects to the network towards the and multi-dropping capabilities. In addition, 19.2K, 38.4K, and 76.8K are switch selectable host and the B side connects to the extended these devices offer field selectable End-of-Line ■ Field-selectable end-of-line network network. Functionally, the A and B sides are Network (EOLN) terminations on both the A and terminations on both A and B sides equivalent. B networks. ■ Electrical transient protection is provided. This Repeaters receive AC power through a 3-screw Operation is transparent to all devices and protects the host computer from destructive terminal strip. Transient signal protection is no handshaking is required. Up to thirty-two noise spikes and other provided on both RS-485 sides. RS-485 devices can be driven. Network repeaters transient signals. are ready to mount on any base plate. Or, for When both RS-485 lines are idle, each side is a harsh environment, it can be installed in a ■ Status LED’s indicate transmission in receive mode. When a ‘1’ to ‘0’ transition is NEMA enclosure of your choice. No enclosure direction, RS-485 bus fault conditions, and detected (signifying a start bit) on either side, is necessary for use in a laboratory or office. power applied. the opposite side’s transmitter is enabled. The Installation requires mounting, connecting power transmitter stays enabled for one character’s time ■ 24/115/230V AC power available and cables, and setting the baud rate. (based on the baud rate switch setting). The ■ No separate transformer required with 24V AC received character is then passed through. Approvals units (4683-TTM-3F) UL/cUL listed: Energy management equipment ■ ■ ■ ■ Tel 248-295-0880 Fax 248-624-9234 sales@acromag.com www.acromag.com 30765 Wixom Rd, Wixom, MI 48393 USA Bulletin #8400-404d RS-485 SIDE A RT RT D _ D COM NC RS-485 SIDE B RT RT D _ D COM 24V DC RTN 24V DC Network Accessories: 4683 Series 4683-TTM RS-485 to RS-485 Network Repeater HOST PC CONNECTIONS TO HOST COMPUTER HOST SIGNALS AT DB25 CONVERTER RX 2 TX B TX 3 RX A TO HOST RTS CTS 13 25 12 24 11 23 10 22 DSR 9 21 COM 8 20 7 7 19 C 6 18 DB25 5 17 COM 4 16 3 15 CD 2 14 1 HOST DE9 OR 5 9 4 RX 3 8 2 TX 7 2 B 6 DE9 1 TX 3 RX A RS485 RS232 COM 5 COM A-N2 C Converter R NOTE: JUMPERED PINS ARE NULL-MODEM CONNECTIONS WHICH ALLOW COMMUNICATION A-N3 BETWEEN THE HOST AND ACROMAG SERIES 4100/4200 R I/O STATIONS. UP TO 32 ANY NODES PER RS485 NETWORK DEVICES SEGMENT A-N30 R MODEL 4683-TTM-XF REPEATER A-N31 SYSTEM CONNECTIONS R -1 OPTION -2 OPTION -3 OPTION EXTENDED NETWORK 115VAC 230VAC 24VAC RS485 RS485 L1 AC (HI) L1 AC (HI) HOT AC (HI) W AC (LO) L2 AC (LO)COM AC (LO) G Ground G Ground G Ground B-N2 B-N3 B-N4 B-N5 B-N32 A-N32 B-N1 SEE UNIT LABEL NC 24VDC 24VDC TO VERIFY POWER COM COM RTN RSSI -4DE 85 A NC RSSI -4DE 85 B T T D D T T D D R R R R REQUIREMENTS IMPORTANT: MODEL 4683-TTM-X UNITS UP TO 32 INCLUDE INTERNAL, FIELD NODES PER SELECTABLE END-OF-LINE (EOL) TERMINATION NETWORK RS485 REPEATER R R R R R RESISTORS FOR THE A AND SEGMENT acromag MODEL 4683-TTM-X B SIDES. THESE ARE ENABLED VIA INTERNAL NOTE: SIDE-A AND SIDE-B EOL JUMPERS. DO NOT USE TERMINATION JUMPERS ENABLED EXTERNAL TERMINATION 1 2 3 4 5 6 7 8 WITH INTERNAL EOL 1 - 600 5 - 9600 2 - 1200 6 - 19.2K BAUD 3 - 2400 7 - 38.4K RATE JUMPERS ENABLED. POWER FAULT 4 - 4800 8 - 76.8K TX TX FAULT A S1 B - A A - B B 120 OHM TERMINATION ANY RS-485 DEVICE RESISTOR REQUIRED S1 - SET BAUD RATE RED RS485 FAULT LED (SIDE B) RED POWER LED TO MATCH BAUD AT END OF NETWORK TRANSMIT DIRECTION RED RS485 FAULT LED (SIDE A) RATE OF NETWORK. OR LAST DEVICE ONLY B-TO-A & A-TO-B S1 - BAUD RATE 1 - 600 5 - 9600 2 - 1200 6 - 19.2K 3 - 2400 7 - 38.4K 4 - 4800 8 - 76.8K The station configuration drawing is for general illustration purposes only. Johnson Controls system customers should instead refer to the Metasys® Network Technical Manual for N2 Bus Communication, or the MS/TP Communication Bus Technical Bulletin for wiring connections using the 4683-TTM-xF repeater. Acromag, Inc. Phone: (248) 295 -0880  Fax: (248) 624 -9234 - 4 -  E-mail: sales@acromag.com  On-Line: http://www.acromag.c om ■ ■ ■ ■ Tel 248-295-0880 Fax 248-624-9234 sales@acromag.com www.acromag.com 30765 Wixom Rd, Wixom, MI 48393 USA All trademarks are property of their respective owners. Copyright © Acromag, Inc. 2013. Data subject to change without notice. Printed in USA 9/2013. RS-485 SIDE A RT RT D _ D COM NC RS-485 SIDE B RT RT D _ D COM 24V DC RTN 24V DC Network Accessories: 4683 Series 4683-TTM RS-485 to RS-485 Network Repeater Switch Variation Switch Operation Slide Switch Slide with arrow Slide opposite to to turn ON. arrow to turn Off. Toggle Switch Depress toward Depress toward EOL Jumpers numbers to turn OPEN to turn Off. Side A (IN) On (Closed). EOL JUMPERS 1 1 2 2 EQUIVALENT CIRCUIT 3 3 (4683 UNITS ONLY) J1J2 J1J2 Status Baud Rate Status EOL EOL LEDs LEDs Switches DISABLED ENABLED Vcc FAULT TX TX FAULT S1 1 - 600 5 - 9600 PWR B A - B B - A A JUMPER PAIR BAUD 2 - 1200 6 - 19.2K (ONE SIDE) RATE 3 - 2400 7 - 38.4K 4 - 4800 8 - 76.8K 86 7 53 4 2 1 1200 OHMS D REMOVE THIS SCREW ON EACH 3 2 1 F1 SIDE TO REMOVE COVER 220 OHMS D FUSE 3AG EOL Jumpers 3 2 1 0.5A, 250V Side B (OUT) 1200 OHMS 1 1 1 1 2 2 2 2 3 3 3 3 J4J3 J1J2 J4J3 J4J3 EOL EOL DISABLED ENABLED NOTE: -3F 24V AC units do not require a separate transformer. 24V AC power from the RS-485 devices may be used. 4683-TTM-1F (115VAC) GW L1 RS-485 RS-485 MODEL 4683-TTM-1F REPEATER G L2 L1 4683-TTM-2F (230VAC) SIDE B SIDE A MODEL 4683-TTM-2F REPEATER G COM HOT 4683-TTM-3F (24VAC) MODEL 4683-TTM-3F REPEATER AC (HI) End-of-Line (EOL) Termination Jumper Locations. COMD D COM D D AC (LO) Input Power Fuse Location. NETWORK CONNECTIONS GROUND 4.30 3.70 (109.22) (93.98) acromag 1 2 3 4 5 6 7 8 1 - 600 5 - 9600 2 - 1200 6 - 19.2K BAUD 3 - 2400 7 - 38.4K RATE FAULT TX TX FAULT 4 - 4800 8 - 76.8K POWER A B - A A - B B S1 0.30 (7.62) 6.40 0.30 TYP (162.56) (7.62) TYP 7.0 (177.80) 2.10 (53.34) ■ ■ ■ ■ Tel 248-295-0880 Fax 248-624-9234 sales@acromag.com www.acromag.com 30765 Wixom Rd, Wixom, MI 48393 USA All trademarks are property of their respective owners. Copyright © Acromag, Inc. 2013. Data subject to change without notice. Printed in USA 9/2013. RS-485 SIDE A R T RT D D COM NC RS-485 SIDE B R T R T D D COM 24VDC RTN 24VDC Network Accessories: 4683 Series 4683-TTM RS-485 to RS-485 Network Repeater ■ Specifications Performance Specifications Ordering Information Power Line Fuse 0.5A, 125V, 0.75A, 3AG type. ■ Communication Specifications Models Isolation Baud Rates 4683-TTM-1F Provides galvanic and opto-coupler isolation between Switch settings on unit for 600, 1200, 2400, 4800, 115V ACPower. RS-485(A), RS-485(B), AC power, and chassis ground. 9600, 19.2K, 38.4K, and 76.8K baud rates. Switch 4683-TTM-2F Common mode voltages are permitted up to 250V must be in the proper baud rate position for proper 230V ACPower. rms or 354V DC (withstands a 1500V AC dielectric operation. 4683-TTM-3F strength test for 1 min. without breakdown) on a RS-485 Bus Loading 24V ACPower. continuous basis. Complies with requirements outlined One unit load equivalent. in ANSI C39.5-1974 for voltage ratings specificed. RS-485 Bus Drive RFI Resistance Complete RS-485 compliance for up to 32 unit loads Withstands an RFI field strength of 10V per meter at Accessories (31 unit loads if a repeater is used). 27 Mhz, 151 Mhz, and 467 Mhz with no digital effect, See www.acromag.com for more information. End-of-Line Termination Network per SAMA PMC 33.1. The EOLN termination network Line Noise Effects is shown on the right and is Field and power line terminals withstand ANSI/IEEE individually selected on both 1200 C37.90-1978 Surge Withstanding Capability (SWC) Ohms the A and B sides by a pair of Test with no component D shorting clips. The A-side is failures. Unit is tested to a standardized test 32 1 220 controlled by jumper pair J1, J2 waveform that is representative of surges Ohms and the B-side is controlled by (high-frequency transient electrical interference), D jumper pair J3 and J4. 32 1 observed in actual installations. 1200 The EOLN termination network Ohms Communications Connections is enabled for the A side or B Network repeater - both RS-485 connectors use side when the associated pair modular terminal blocks with screw clamps. Wire of jumpers are positioned over range 14 to 26 AWG. pins 1 and 2. Conversely, the EOLN is disabled (out of Power Wire Connections the circuit) when the pair jumpers are positioned over Network repeater terminal block. See label on unit for pins 2 and 3. power to be applied to unit. Duplex Shipping Weight Half duplex only. 3.0 pounds (1.4 kg) packed per unit. Data Format ■ Environmental Ten bits typical (1 start bit, 8 data bits, and 1 stop bit). Other formats are supported. Operating temperature -25 to 70° C (-13 to 158° F) Storage temperature -25 to +85° C (-13 to 185° F) Relative humidity 0 to 95% RH (noncondensing), up to 40° C (104° F). Power 4683-TTM-1F 115VAC ±10%, 50/60 Hz, 0.05A 4683-TTM-2F 230VAC ±10%, 50/60 Hz, 0.03A 4683-TTM-3F 24VAC ±10%, 50/60 Hz, 0.18A typical Approvals UL/cUL listed – energy management equipment. ■ ■ ■ ■ Tel 248-295-0880 Fax 248-624-9234 sales@acromag.com www.acromag.com 30765 Wixom Rd, Wixom, MI 48393 USA All trademarks are property of their respective owners. Copyright © Acromag, Inc. 2013. Data subject to change without notice. Printed in USA 9/2013

Related Products

None available

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.043 seconds.