CRYDOM 84134030
Specifications
Part Number
84134030
Product Series
841
Control Voltage
3 to 32VDC
Amp Rating
75 Amp
Type of Relay
Hockey Puck
Output Switching
Zero Crossing
Operating Voltage
280VAC
Phase
Single Phase
Ratings
No
Availability
Standard Stock
Weight - lbs.
0.2100
Base Unit of Measure
Each
Categorization Information
Solid State Relays
SSR, Hockey Puck, 75A, 3-32VDC Control Voltage,-84134030
Features
- 25, 50 or 75 Amp Models
- 3-32VDC or 90-280VAC input
- 24-280VAC output
- Zero Crossing
- Back to back SCR's for severe inductive loads
- Direct bond copper substrate
- Improved power lead frame design
- LED input status indicator
- Available with IP20 touchsafe cover
- All approvals
- Replaces # G240D25
Datasheet
crouzet-ssr-datasheet.pdf
234 KiB
Extracted Text
GN Series Solid State Relays � � Current ratings from 10 to 125 amps Transient protection built in IP20 � � Output voltage from 24 to 660 Vac 4000 Vac optical isolation � � Back to back SCR’s for severe Available with IP20 inductive loads “touch-safe” cover � � Direct bond copper substrate UL E79183, CSA LR � 38595, TUV Approved, Improved power lead frame design CE Compliant � LED input status indicator IP00 Output Specifications Part Numbers Voltage range (Vrms) 24 - 280Vac 48 - 660Vac (Zero Crossing) Peak Voltage (Vpk, t = 1 min.) 600 1200 Rating Output Input IP00 IP20 Off-state leakage .1mArms .25mArms 10 Amp 24-280Vac 90-280Vac 84 134 001 84 137 001 (@ max. line voltage & Ta = 25°C) 0.1 0.25 3-32Vdc 84 134 000 84 137 000 48-660Vac 90-280Vac 84 134 101 84 137 101 Output Current (Mounted on 10 25 50 75 100 125 3-32Vdc 84 134 100 84 137 100 proper heat sink, see deratings) 25 Amp 24-280Vac 90-280Vac 84 134 011 84 137 011 Minimum Current (mArms) 50 50 100 100 100 100 3-32Vdc 84 134 010 84 137 010 Max. 1 cycle surge current 150 300 750 1000 1200 1700 48-660Vac 90-280Vac 84 134 111 84 137 111 (Apk, Ta = 25°C) 3-32Vdc 84 134 110 84 137 110 Max. 1 second surge current 30 75 150 225 300 375 50 Amp 24-280Vac 90-280Vac 84 134 021 84 137 021 (Apk, Ta = 25°C) 3-32Vdc 84 134 020 84 137 020 Forward voltage drop 1.35 1.35 1.35 1.3 1.3 1.3 48-660Vac 90-280Vac 84 134 121 84 137 121 (Vpk @ Imax, Ta = 25°C) 3-32Vdc 84 134 120 84 137 120 2 1 I T (60Hz, /2 cycle) 416 937 2458 5000 6000 12.041 75 Amp 24-280Vac 90-280Vac 84 134 031 84 137 031 Rjb (thermal res. Junction to 0.5 0.4 0.25 0.16 0.155 0.15 3-32Vdc 84 134 030 84 137 030 baseplate, °C/W) 48-660Vac 90-280Vac 84 134 131 84 137 131 Static off-state dv/dt 500 500 500 500 500 500 3-32Vdc 84 134 130 84 137 130 (Vµs, Ta = 25°C) 100 Amp 24-280Vac 90-280Vac 84 134 041 84 137 041 Minimum heat sink @ ambient 3.0@ 1.5@ 1.0@ 0.7@ 0.6@ 0.4@ 3-32Vdc 84 134 040 84 137 040 (for max current = °C/W & Ta) 70°C 50°C 40°C 40°C 40°C 40°C 48-660 90-260Vac 84 134 141 84 137 141 Input Specifications 3-32Vdc 84 134 140 84 137 140 Input voltage* 3-32Vdc 90-280Vac* 125 Amp 24-280Vac 90-280Vac 84 134 081 84 137 081 Drop out voltage 1Vdc 10Vrms 3-32Vdc 84 134 080 84 137 080 Max. input current 14mA 10mArms 48-660Vac 90-280Vac 84 134 181 84 137 181 Min. input current (for on-state) 7mA 5mArms 3-32Vdc 84 134 180 84 137 180 Input Resistance Current Regulated Random SSR’s Turn-on time** 8.33ms 20ms Rating Output Input IP00 IP20 Turn-off time 8.33ms 30ms 10 Amp 24-280Vac 3-32Vdc 84 134 200 84 137 200 *4-32Vdc for 48-660Vac models 48-660Vac 3-32Vdc 84 134 300 84 137 300 **Random SSR’s turn on in less than 100µs 25 Amp 24-280Vac 3-32Vdc 84 134 210 84 137 210 General Characteristics 48-660Vac 3-32Vdc 84 134 310 84 137 310 Operating Temperature (°C) -20 to +80 50 Amp 24-280Vac 3-32Vdc 84 134 220 84 137 220 Storage Temperature (°C) -40 to +100 48-660Vac 3-32Vdc 84 134 320 84 137 320 Input to output isolation 4000Vrms 75 Amp 24-280Vac 3-32Vdc 84 134 230 84 137 230 Input/output to ground isolation 2500Vrms 48-660Vac 3-32Vdc 84 134 330 84 137 330 Input to output capacitance 8pF (typical) 100 Amp 24-280Vac 3-32Vdc 84 134 240 84 137 240 Operating Frequency 47 to 63 Hz 48-660Vac 3-32Vdc 84 134 340 84 137 340 Housing Material UL 94V0 (self extinguishing) 125 Amp 24-280Vac 3-32Vdc 84 134 280 84 137 280 Safety and Noise Immunity Compliance 48-660Vac 3-32Vdc 84 134 380 84 137 380 CE Compliant with the LVD 73/23/EEC Dimensions – see page 1-12 UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91 TUV EN60950 IEC 1000-4-2: Electrostatic Discharge – Level 3 IEC 1000-4-3: Radiated Electromagnetic Noise – Level 3 IEC 1000-4-4: Electrically Fast Transients – Level 3 IEC 1000-4-5: Electrical Surges – Level 3 IEC 1000-4-6: Conducted Electromagnetic Noise – Level 3 CISPR 11 – Class A: Allowable Levels of Conducted and Radiated Noise for Industrial Environments *For Ambient temperatures above 40°C the maximum control voltage must not exceed 250Vac. Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-10 1/L1 2/T1 4/A2 3/A1 1/L1 2/T1 4/A2 3/A1 DIMENSIONS IN INCHES INPUT OUTPUT DERATING CURVES DERATE CURVES: DERATE CURVES: GN SSR-10 AMP TRIAC OUTPUT GN SSR-25 AMP TRIAC OUTPUT Ambient Temperature (°C) Ambient Temperature (°C) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-12 Load Current (Amperes) Load Current (Amperes) DERATE CURVES: DERATE CURVES: GN SSR-10 AMP SCR OUTPUT GN SSR-25 AMP SCR OUTPUT (1200 & 600V) 1 Ambient Temperature (°C) Ambient Temperature (°C) DERATE CURVES: DERATE CURVES: GN SSR-50 AMP SCR OUTPUT (1200 & 600V) GN SSR-75 AMP SCR OUTPUT (1200 & 600V) 0.5°C/W 0.7°C/W 1.0°C/W 1.5°C/W Ambient Temperature (°C) Ambient Temperature (°C) DERATE CURVES: DERATE CURVES: GN SSR-100 AMP SCR OUTPUT (1200 & 600V) GN SSR-125 AMP SCR OUTPUT (1200 & 600V) Ambient Temperature (°C) Ambient Temperature (°C) Products and specifications subject to change without notice. Consult factory for application assistance. 204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com 1-13 Load Current (Amperes) Load Current (Amperes) Load Current (Amperes) Load Current (Amperes) Load Current (Amperes) Load Current (Amperes)
Frequently asked questions
Why choose IPC Station?
What is IPC Station' warranty policy for the 84134030?
What carriers does IPC Station use to ship parts?
Does IPC Station sell to international (non-USA) customers?
What methods of payment does IPC Station accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods