Part Number | EKI-1321-AE |
---|---|
Manufacturer | ADVANTECH |
Category | Serial Device Servers » Serial Device Servers |
Price | Request Quote |
Lead Time | Request Quote |
EKI-1321 and EKI-1322 cellular gateways can transparently bring RS-232/422/485 or Ethernet devices to a cellular network. They allow nearly any device with serial or Ethernet ports to connect and share a cellular network with easy and simple configuration. EKI-1321 and EKI-1322 GPRS IP Gateway's are compact, and can be DIN-rail or wall mounted and with both front panel and side panel LED displays for easy identification. They come with dual DC power input from 12 to 48 VDC and have 2 KV EFT/Surge protection to prevent damage from various type of power resources. The serial ports are also protected by 15 KV ESD line protection to keep your system safe from unexpected electrical discharges. Both models support dual SIM slots to support GPRS signal redundancy to switch to an available channel automatically while the existing one is disconnected, and SD card slot for data buffering to prevent loss of serial data while the communication is interrupted.
Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.
Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.
Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.
Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.
Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.
Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.
After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.
IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.
Do you need an EKI-1321-AE? We can help you find it at a competitive price!
Cellular Interface Band Option | Quad-band 850/900 and 1800/1900 MHz |
---|---|
Cellular Interface GPRS Coding Schemes | CS1 ~ CS4 |
Cellular Interface GPRS Multi-Slot | Class 10 |
Cellular Interface GPRS Terminal Device | Class B |
Cellular Interface No. of SIM | 2 |
Cellular Interface SIM Control | 3 V |
Cellular Interface Standards | GSM/GPRS |
Cellular Interface Tx Power | 1 W for GSM 1800/1900, 2 W for EGSM 850/900 |
Digital Input Channels | 2 |
Digital Input Input Level | Logic level 0: 1 V Maximum, Logic level 1: 3 ~ 30 V |
Environment Operating Humidity | 5 ~ 95% RH |
Environment Operating Temperature | -30 ~ 65°C (-22 ~ 149°F) |
Environment Storage Temperature | -40 ~ 75°C (-40 ~ 167°F) |
General LED Indicators | System: Power, System Status, GPRS: Quality, GPRS ready; Serial: Tx, Rx |
General Reboot Trigger | Built-in WDT (watchdog timer) |
LAN Interface Connector | RJ45 |
LAN Interface Ethernet | 10/100 Mbps, auto MDI/MDIX |
LAN Interface Protection | 1.5 KV built-in magnetic isolation protection |
Mechanics Dimensions (W x H x D) | 27 x 120 x 85 mm (1.06" x 4.72" x 3.35") |
Mechanics Enclosure | Metal with solid mounting hardware |
Mechanics Mounting | DIN-rail, Wall |
Mechanics Weight | 0.49 Kg |
Power Requirements Power Connector | Terminal block |
Power Requirements Power Consumption | 8W |
Power Requirements Power EFT/Surge Prot. | 2 KV |
Power Requirements Power Input | 12 ~ 48 VDC, redundant dual inputs |
Relay Output Channels | 1 |
Relay Output Contact Rating | 0.5 A @ 120 VAC |
Relay Output Relay off Time(Typ.) | 4 ms |
Relay Output Relay on Time(Typ.) | 3 ms |
Serial Communication Baud Rate | 75 bps to 921.6 kbps, any baud rate setting |
Serial Communication Data Bits | 5, 6, 7, 8 |
Serial Communication No. of Ports | 1, 2 KV isolation protection |
Serial Communication Parity | None, Odd, Even, Space, Mark |
Serial Communication Port Connector | DB9 male |
Serial Communication Port Type | RS-232/422/485, software selectable |
Serial Communication Protection | 15 KV ESD for all signals |
Serial Communication Serial Signals | RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND, RS-422: TxD+, TxD-, RxD+, RxD-, GND, RS-485: Data+, Data-, GND |
Serial Communication Stop Bits | 1, 1.5, 2 |
Software Configuration | Windows utility, Telnet console, Web Browser |
Software Driver Support | 32-bit/64-bit Windows 2000/XP/Vista/7, Windows Server 2003/2008, Windows CE 5.0, and Linux |
Software Operation Modes | Virtual COM, Reverse Virtual COM, TCP/UDP server mode, TCP/UDP client mode, Pair connection mode (Serial Tunnel), RFC2217, SMS Tunnel, IP Gateway w/ VPN |
Software Protocols | ICMP, TCP/IP, UDP, DHCP Client, Telnet, DNS, SNMP, HTTP, HTTPS, SMTP, SNTP, ARP, SSL |
Software Router/Firewall | NAT, port forwarding |
Software Utility Software | Advantech Serial Device Server Configuration Utility |
Categorization Information | Intelligent Connectivity Industrial Communication Serial Device Servers |
Download "9143df48-02da-47e9-b6de-4ab9660a6724.pdf" (452 KiB)
1-port RS-232/422/485 to GPRS IP EKI-1321 Gateway 2-port RS-232/422/485 to GPRS IP EKI-1322 Gateway Features NEW Universal quad-band GSM/GPRS 850/900/1800/1900 MHz Dual SIM for telecom redundancy Supports SDHC SD Card for Data Buffering Connects Ethernet and Serial Devices over VPN Various operation modes: COM port redirector, RVCOM, TCP, UDP, SMS tunnel, and pair connection Any baud rate setting for easy configuration Built-in 15 KV ESD protection for all serial signals 1.5 KV isolation protection (EKI-1321) 2 digital inputs (EKI-1321) Multiple configuration methods: Windows utility, Telnet, and Web console EKI-1321 EKI-1322 RoHS COMPLIANT 2011/65/EU Introduction EKI-1321 and EKI-1322 cellular gateways can transparently bring RS-232/422/485 or Ethernet devices to a cellular network. They allow nearly any device with serial or Ethernet ports to connect and share a cellular network with easy and simple configuration. EKI-1321 and EKI-1322 GPRS IP Gateway's are compact, and can be DIN-rail or wall mounted and with both front panel and side panel LED displays for easy identification. They come with dual DC power input from 12 to 48 V and have 2 KV EFT/Surge protection to prevent damage DC from various type of power resources. The serial ports are also protected by 15 KV ESD line protection to keep your system safe from unexpected electrical discharges. Both models support dual SIM slots to support GPRS signal redundancy to switch to an available channel automatically while the existing one is disconnected, and SD card slot for data buffering to prevent loss of serial data while the communication is interrupted. Specifications LAN Interface General Ethernet 10/100 Mbps, auto MDI/MDIX LED Indicators System: Power, Status Connector RJ45 GPRS: Quality, ready Protection 1.5 KV built-in magnetic isolation protection Serial: Tx, Rx Ethernet: Speed, Link/Active Cellular Interface Reboot Trigger Built-in WDT (watchdog timer) Standards GSM/GPRS Software Band Option Quad-band 850/900 and 1800/1900 MHz GPRS Multi-Slot Class 10 Driver Support 32-bit/64-bit Windows XP/Vista/7/8, Windows Server GPRS Terminal Device Class B 2003/2008/2008 R2/2012, Windows CE 5.0, and Linux GPRS Coding Schemes CS1 ~ CS4 Utility Software Advantech EKI Device Configuration Utility Tx Power 1 W for GSM 1800/1900, 2 W for EGSM 850/900 Operating Modes Virtual COM, Reverse Virtual COM, TCP/UDP server mode, No. of SIM 2 TCP/UDP client mode, Pair connection mode (Serial Tunnel), SIM Control 3 V RFC2217, SMS Tunnel, IP Gateway w/ VPN Configuration Windows utility, Telnet console, Web Browser Serial Communications Protocols ARP, ICMP, IPv4, IPv6, TCP, UDP, BOOTP, DHCP Client, Auto IP, Port Type RS-232/422/485, software selectable Telnet, DNS, SNMP, HTTP, HTTPS, SMTP, SNTP, SSL No. of Ports EKI-1321: 1, 2 KV isolation protection Router/Firewall NAT, port forwarding EKI-1322: 2 Port Connector DB9 male Mechanics Data Bits 5, 6, 7, 8 Dimensions (W x H x D) 27 x 120 x 85 mm (1.06" x 4.72" x 3.35") Stop Bits 1, 1.5, 2 Enclosure Metal with solid mounting hardware Parity None, Odd, Even, Space, Mark Mounting DIN-rail, Wall Baud Rates 75 bps to 921.6 kbps, any baud rate setting Weight 0.49 Kg Serial Signals RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND RS-422: TxD+, TxD-, RxD+, RxD-, GND Power Requirements RS-485: Data+, Data-, GND Protection 15 KV ESD for all signals Power Input 12 ~ 48 V , redundant dual inputs DC Power Connector Terminal block Relay Output Power Consumption EKI-1321: 8W, EKI-1322: 8.5W Power EFT/Surge Prot. 2 KV Channel 1 Contact Rating 0.5 A @ 120 VAC Environment 0.25 A @ 240 V ; 2 A @ 30 V AC DC Relay off Time(Typ.) 4 ms Operating Temperature -30 ~ 65°C (-22 ~ 149°F) Relay on Time(Typ.) 3 ms Storage Temperature -40 ~ 75°C (-40 ~ 167°F) Operating Humidity 5 ~ 95% RH Digital Input (EKI-1321) Regulatory Approvals Channel 2 Input Level Logic level 0: 1 V Maximum EMC CE: EN55022/EN55024, Class A Logic level 1: 3 ~ 30 V FCC: FCC part 15 subpart B, Class A RF FCC Part22H/Part24E, EN301 489-1, EN301 489-7, EN301 511 Industrial Wireless Solutions All product specifications are subject to change without notice Last updated : 5-May-2015 EKI-1321 EKI-1322 39.10 35 Dimensions Unit: mm [inch] [1.539] [1.378] 8.70 [0.343] EKI-1321 94 [3.700] 85 [3.346] 36.60 40 27 [1.063] 85 [3.346] 27 [1.063] [1.441] [1.575] Panel Cut-out Dimensions: 94 x 120 x 27 mm (3.700" x 4.724" x 1.063") 39.10 35 EKI-1322 [1.539] [1.378] 8.70 [0.343] 94 [3.700] 85 [3.346] 36.60 40 27 [1.063] 85 [3.346] 27 [1.063] [1.441] [1.575] Panel Cut-out Dimensions: 94 x 120 x 27 mm (3.700" x 4.724" x 1.063") Ordering Information EKI-1321 1-port GPRS IP Gateway EKI-1322 2-port GPRS IP Gateway OPT1-DB9 D-Sub 9 to Terminal Converter Online Download www.advantech.com/products 12.60 12.60 9.80 9.80 [0.496] [0.496] [0.386] [0.386] 120 [4.724] 120 [4.724] 18.90 18.90 [0.744] [0.744] 37.95 37.95 [1.494] [1.494] 47.05 [1.852] 47.05 [1.852] 120 [4.724] 120 [4.724] 129.80 [5.110] 129.80 [5.110] 129.80 [5.110] 129.80 [5.110]
Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.
GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.
All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.