Description

A strain gauge input module uses a microprocessor-controlled integrating A/D converter to convert sensor voltage or current signals into digital data for load cell and stress measurement. The digital data is then translated into either engineering units, twos complement hexadecimal format or percent-age of full-scale range (FSR)according to the module 's configuration. When prompted by the host computer, the data is sent through a standard RS-485 interface. The strain gauge input module offers signal conditioning, A/D conversion, ranging, and RS-485 digital communication functions. They protect your equipment from ground loops and power surges by providing opto-isolation of the A/D input and transformer based isolation up to 3000 VDC.

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need an ADAM-4016? We can help you find it at a competitive price!

Specifications

Categorization Information Industrial Automation
Remote I/O Modules
RS-485 I/O Modules: ADAM-4000
Analog I/O Modules

Features

  • Strain Gauge Input
  • Watchdog Timer

Datasheet

Download "213b0997-05d1-43c5-9830-d43a0a4c9333.pdf" (236 KiB)

Extracted Text

6-ch RTD Module with Modbus ADAM-4015 ADAM-4015T 6-ch Thermistor Module with Modbus ADAM-4016 1-ch Analog Input/Output Module RoHS RoHS RoHS ADAM-4015 COMPLIANT ADAM-4015T COMPLIANT ADAM-4016 COMPLIANT 2002/95/EC 2002/95/EC 2002/95/EC Specifications Specifications Specifications General General General ƒ Connectors 2 x plug-in terminal blocks ƒ Connectors 2 x plug-in terminal blocks ƒ Connectors 2 x plug-in terminal blocks (#14 ~ 28 AWG) (#14 ~ 22 AWG) (#14 ~ 28 AWG) ƒ Power Consumption 1.2 W @ 24 V DC ƒ Power Consumption 2.2 W @ 24 V DC ƒ Power Consumption 1.2 W @ 24 V DC ƒ Watchdog Timer System (1.6 s) & ƒ Watchdog Timer System (1.6 s) ƒ Watchdog Timer System (1.6 s) & Communication ƒ Supported Protocols ASCII command Communication ƒ Supported Protocols ASCII command and Modbus/RTU Analog Input ƒ Supported Protocols ASCII command and ƒ Burn-out Detection Yes Modbus/RTU ƒ Channels 1 differential ƒ Input Impedance Voltage: 2 MΩ ƒ Burn-out Detection Yes Analog Input Current: 125 Ω ƒ Channels 6 differential (Added by user) Analog Input ƒ Input Connections 2, 3-wire ƒ lnput Type mV or mA ƒ Channels 6 differential ƒ Input Impedance 10 MΩ ƒ lnput Range ±15 mV, ±50 mV, ±100 mV, ƒ Input Type Pt, Balco and Ni RTD ƒ Input Connections 2, 3-wire ±500 mV, ±20 mA ƒ RTD Types and Temperature Ranges ƒ Input Impedance 10 MΩ ƒ Accuracy Voltage mode: ±0.1% or Pt 100 RTD: better ƒ Input Type Thermistor (NTC) Pt -50°C to 150°C Current mode: ±0.2% or Pt 0°C to 100°C ƒ Thermistor Types and Temperature Ranges better Pt 0°C to 200°C Thermistor 3 k 0 ~ 100°C ƒ CMR @ 50/60 Hz 150 dB Pt 0°C to 400°C Thermistor 10 k 0 ~ 100°C ƒ Span Drift ±25 ppm/°C Pt -200°C to 200°C ƒ Accuracy ±0.1% or better ƒ Zero Drift ±6 µV/°C IEC RTD 100 ohms (a = 0.00385) ƒ CMR @ 50/60 Hz 120 dB JIS RTD 100 ohms (a = 0.00392) Analog Output Pt 1000 RTD ƒ Span Drift ± 25 ppm/°C ƒ Channels 1 Pt -40°C to 160°C ƒ Zero Drift ± 3 µV/°C ƒ Accuracy 0.05% of FSR Balco 500 RTD -30°C to 120°C ƒ Output Type V Ni 50 RTD ƒ Output Range 0 ~ 10 V Ni -80°C to 100°C ƒ Drift ±50 ppm/°C Ni 508 RTD ƒ Drive Current 30 mA Ni 0°C to 100°C ƒ Isolation Voltage 3,000 VDC BA1 Digital Output -200°C to 600°C ƒ Accuracy ±0.1% or better ƒ Channels 4, open collector to ƒ CMR @ 50/60 Hz 120 dB 30 V, 30 mA max. load ƒ Span Drift ± 25 ppm/°C ƒ Power Dissipation 300 mW ƒ Zero Drift ± 3 µV/°C Common Specifications Ordering Information ƒ ADAM-4015 6-ch RTD Input Module Environment General with Modbus ƒ Power Input Unregulated 10 ~ 30 V ƒ Operating Humidity 5 ~ 95% RH DC ƒ ADAM-4015T 6-ch Thermistor Input ƒ Operating - 10 ~ 70°C Module with Modbus Analog Input Temperature (14 ~ 158°F) ƒ ADAM-4016 1-ch Analog Input/ ƒ Resolution 16-bit ƒ Storage Temperature - 25 ~ 85°C Output Module ƒ NMR @ 50/60 Hz 100 dB (-13 ~ 185°F) ƒ Sampling Rate 10 sample/second (total) ƒ Isolation Voltage 3,000 V DC Online Download www.advantech.com/products All product specifications are subject to change without notice Last updated : 5-May-2015

Related Products

ADVANTECH
The ADAM-4017 is a 16-bit, 8-channel analog input module that provides prog...
ADVANTECH
The ADAM-4017/4018 is a 16-bit,8-channel analog input module that provides...
ADVANTECH
The ADAM-4050 features seven digital input channels and eight digital outpu...
ADVANTECH
The ADAM-4052 provides eight digital input channels: six fully independent...
ADVANTECH
The ADAM-4053 provides 16 digital input channels for dry contact or wet con...
ADVANTECH
12-channel Source Type Isolated Digital Output Module

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 6.604 seconds.