Industry Pack I-O Products/Analog I-O

ACROMAG IP340E

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number IP340E
Manufacturer ACROMAG
Category Industry Pack I/O Products »  Analog I/O
Price Request Quote
Lead Time Request Quote

Description

IP340: Analog Input Module, Simultaneous Sample & Hold
IP340/341 Industrial I/O Pack (IP) modules provide fast, high resolution, simultaneous A/D conversion of up to eight channels. These modules have sixteen analog inputs which are sampled as two eight-channel banks. Eight A/D converters (ADCs) permit simultaneous conversion of all eight channels in a bank. A FIFO buffer holds the first bank's data while the second bank is converted. Conversion of each bank requires only 8µS, and all 16 channels can be sampled in just 16µs. Flexible configuration options give you extensive control over the conversion process. The channels or bank to be converted, timing, scan mode, and other parameters are user-programmable. Interrupt support adds further control to flag a FIFO that is full or filled to a user-defined threhold level.Analog input module with 16 differential inputs (8 simultaneous sample & hold conversions), 12-bit A/D, 125KHz throughput.Analog input module with 16 differential inputs (8 simultaneous sample & hold conversions), 12-bit A/D, 125KHz throughput, extended temperature range.

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need an IP340E? We can help you find it at a competitive price!

Specifications

Categorization Information Embedded I/O & Processors
Industry Pack I/O Products
Analog I/O
IP300 Series

Features

  • 16 differential inputs (two 8-channel groups)
  • 12 or 14-bit A/D
  • 125KHz throughput
  • 8µS conversion time for 8-channel group
  • 512 sample FIFO buffer, ±10V input range
  • 16 differential inputs (±10V DC input range)
  • Eight 12 or 14-bit A/D converters (IP340/341) with simultaneous sample and hold capability
  • 8µS conversion time (125KHz) for 8-channel bank
  • FIFO buffer with 512 sample memory
  • Programmable conversion timer
  • Programmable channel conversion control
  • External trigger input and output
  • Continuous and single-cycle conversion modes
  • Interrupt generation for FIFO threshold conditions
  • Precision calibration voltages stored on-board
  • 0 to 70°C (IP340/341) or -40 to 85°C (IP340E/341E models)

Datasheet

Download "CoV-IP340_IP341.pdf" (81 KiB)

Extracted Text

Industry Pack Modules Industry Pack Modules IP340 and IP341 Simultaneous A/D Conversion Analog Input IP340/341 Industry Pack (IP) modules provide fast, high resolution, simultaneous A/D conversion of up to The IP340 is ideal for high-speed data acquisition. A large FIFO buffer reduces CPU interactions for increased overall performance eight channels. These modules have sixteen analog inputs which are Environmental Specifications Operating temperature: 0 to 70°C (IP340/341) sampled as two eight-channel banks. Eight A/D Analog Inputs or -40 to 85°C (IP340E/341E models). converters (ADCs) permit simultaneous conversion of Input configuration: 16 differential. Storage temperature: -40 to 125°C (all models). all eight channels in a bank. A FIFO buffer holds the A/D resolution: 12 bits (IP340), 14 bits (IP341). Relative humidity: 5 to 95% non-condensing. first bank’s data while the second bank is converted. Input range: ±10V. MTBF: 594,898 hrs at 25°C, MIL-HDBK-217F, Notice 2. Conversion of each bank requires only 8μS, and all Data sample memory: 512 sample FIFO buffer. 16 channels can be sampled in just 16μs. Power: Max. throughput rate: +5V: 65mA (IP340/341), 76mA ( IP340E/341E). Flexible configuration options give you extensive control Eight channels can be simultaneously acquired. +12V from P1: 7mA. One channel: 125KHz (8μS/conversion) over the conversion process. The channels or bank to be -12V from P1: -6mA. 8 channels (same bank): 1MHz (8μS/8 channels) converted, timing, scan mode, and other parameters are 16 channels (high & low banks): 1MHz (16μS/16 ch.at user-programmable. Interrupt support adds further Ordering Information minimum 2.2K ohm source resistance). control to flag a FIFO that is full or filled to a user- Data sample memory: 512-sample FIFO memory buffer. Industry Pack Modules defined threshold level. IP340 A/D triggers: Internal timer, external, and software. 12-bit A/D System accuracy: Features IP340E IP340: 1.6 LSB (0.039%), n 16 differential inputs (±10V DC input range) Same as IP340 plus extended temp. range. IP341: 2.4 LSB (0.014%). IP341 Data format: Binary two’s compliment. n Eight 12 or 14-bit A/D converters (IP340/341) with 14-bit A/D Input overvoltage protection: ±25V with power on, ±40V simultaneous multi-channel conversion IP341E with power off. Same as IP341 plus extended temp. range. n 8μS conversion time (125KHz) for 8-channel bank Common mode rejection ratio (60Hz): 96dB typical. Acromag offers a wide selection of Industry Pack Carrier Cards. Channel-to-channel rejection ratio (60Hz): 96dB typical. n FIFO buffer with 512 sample memory Software (see software documentation for details) IP Compliance (ANSI/VITA 4) n Programmable conversion timer IPSW-API-VXW Meets IP specifications per ANSI/VITA 4-1995. ® VxWorks software support package n Programmable channel conversion control IP data transfer cycle types supported: Input/output (IOSel*), IPSW-API-QNX ID read (IDSel*), Interrupt select (INTSel*). n External trigger input and output ® QNX software support package Access times (8MHz clock): IPSW-API-WIN n Continuous and single-cycle conversion modes ID space read: 0 wait states (250ns cycle). ® Windows DLL driver software support package FIFO buffer read: 2 wait states maximum (500nS), n Interrupt generation for FIFO threshold conditions 1 wait state typical (375nS). IPSW-LINUX ™ Registers read/write: 0 wait states (250ns cycle). Linux support (website download only) n Precision calibration voltages stored on-board Interrupt read/write: 0 wait states (250ns cycle). See accessories documentation for additional information. Benefits n Simultaneous channel conversion and on-board memory enable megahertz throughput rates. n Programmable interrupts simplify data acquisition by providing greater control. All trademarks are the property of their respective owners. Acromag, Inc. • PO Box 437, Wixom, MI 48393 • Phone: 248-295-0310 • Fax: 248-624-9234 • solutions@acromag.com • www.acromag.com 8400-262 Printed in USA 6/05 Copyright © 2005 Acromag, Inc. Data subject to change without notice Industry Pack Modules

Related Products

ACROMAG
IP220A: Analog Output Industry Pack Module, 12-bit D/A The IP220A outputs a...
ACROMAG
IP230A: Analog Output Module, 16-bit D/A IP230A modules have a 16-bit D/A c...
ACROMAG
IP230A: Analog Output Module, 16-bit D/A IP230A modules have a 16-bit D/A c...
ACROMAG
IP235A: Analog Output Module, 16-bit D/A w/RAM Buffer IP235A modules have a...
ACROMAG
IP235A: Analog Output Module, 16-bit D/A w/RAM Buffer IP235A modules have a...
ACROMAG
IP330A: Analog Input Module, 16-bit A/D IP330A Industrial I/O Pack (IP) mod...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 8.614 seconds.