Signal Conditioners & Converters/Signal Converters, Transmitters

ACROMAG 841T-0500

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number 841T-0500
Manufacturer ACROMAG
Category Signal Conditioners & Converters »  Signal Converters, Transmitters
Price Request Quote
Lead Time Request Quote

Description

Intelligent Transmitter, DC Frequency/Pulse Input
Acromag's IntelliPack® series is a family of high-performance, multi-function I/O modules. IntelliPacks feature universal input/output ranges and an intelligent microcontroller to provide extreme flexibility and powerful signal conditioning capabilities. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions. The 841T transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function. Setup is very easy. IntelliPack modules are quickly configured with the user-friendly Windows software program. Field adjustments are simple with the module's frontpanel push-buttons and status LEDs. Once configured, IntelliPacks operate independent of any host computer. Transmitter, frequency and pulse counter input

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 841T-0500? We can help you find it at a competitive price!

Specifications

Categorization Information Signal Conditioners & Converters
Signal Converters, Transmitters
Frequency Input
IntelliPack 800T Series

Features

  • 0 to 50KHz, 0 to 65535 pulses input
  • 0 to 20mA DC, 0 to 10V DC output
  • Mechanical alarm relay (25V @ 5A)
  • 10-36V DC power
  • Software configured; pulse counter; signal averaging; optional limit alarm functions
  • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise.
  • Advanced microcontroller provides intelligent signal processing power for linearization, averaging, and square root computations.
  • Windows XP/Vista/7 software configuration speeds setup and replacement.
  • Multi-purpose inputs and outputs reduce spare stock requirements.
  • Relay output option provides local limit alarm capability.
  • Operating temperature range: -25 to 70°C (-13 to 158°F).
  • All IntelliPacks require initial software configuration (order 800C-SIP).

Datasheet

Download "IntelliPack_Overview_0.pdf" (241 KiB)

Extracted Text

8400100.qxp 3/20/2006 3:19 PM Page 94 ® IntelliPack 800 Series Transmitter w/alarm Alarm N.O. COM N.C. SPDT Relay Signal (841T-1500) Conditioning and Isolation Input Output Current Intelligent DC Voltage or I+ Out JMP Transfer Current Ouput Voltage Out V+ Functions R R L L RTN Power DC- DC+ 10 - 36V DC Power Frequency or TTL Signal Dry Contact EXC+ EXC+ + Frequency FQ-IN FQ-IN Generator n Description BRTN BRTN 841T - EXC- EXC- CRST CRST These transmitters isolate and convert sensor CRTN CRTN Transmitters inputs to noise-free, proportional DC current or voltage output signals. An optional relay Magnetic Pickup or Turbine Flowmeter NAMUR Frequency, output adds a local limit alarm function. EXC+ EXC+ Pulse Counter Input Speed FQ-IN FQ-IN or Flow Each unit offers a selection of input and out- BRTN BRTN Sensor EXC- EXC- Models put ranges, as well as several signal condi- CRST CRST CRTN CRTN 841T-0500: Frequency input transmitter tioning options. This flexibility enables a sin- 841T-1500: Transmitter with limit alarm gle IntelliPack to handle a broad range of Open Collector Open Collector applications. As your needs change, you can PNP NPN V+ V+ Input Ranges easily reconfigure the unit for different or EXC+ EXC+ FQ-IN Sensor types: TTL, dry contact, open collector FQ-IN OR ranges or functions. BRTN BRTN EXC- EXC- NPN/PNP, NAMUR, magnetic pickups, proximity CRST CRST Setup is very easy. IntelliPack modules are CRTN CRTN Frequency: 0 to 100Hz, 0 to 1KHz, 0 to 50KHz quickly configured with the user-friendly Pulse: 0 to 65535 pulses Windows software program. Field adjust- ments are simple with the module’s front- n Performance Output Ranges panel push-buttons and status LEDs. Once con- 0 to 1mA, 0 to 20mA, 4 to 20mA DC n General Input figured, IntelliPacks operate 0 to 5V, 0 to 10V DC Resolution independent of any host computer. Input Range Resolution Limit Alarm 0 to 100Hz 0.01Hz n Special Features SPDT electro-mechanical relay (-1500 unit only) 0 to 1000Hz 0.1Hz 0 to 50,000Hz 1Hz n High-resolution Sigma-Delta A/D converter 0 to 65,535 pulses 1 pulse Power Requirement delivers high accuracy with low noise. 10 to 36V DC Noise Rejection n Advanced microcontroller provides intelligent Common Mode: Better than 80dB @ 60Hz. signal processing power for linearization, Approvals Input Response Time (for input step change) averaging, and square root computations. UL, cUL listed. -3dB @ 35KHz. n Windows XP/Vista/7 software Input Overvoltage Protection configuration speeds setup and replacement. Bipolar Transient Voltage Suppressors (TVS). n Multi-purpose inputs and outputs reduce Continued on next page. spare stock requirements. n Relay output option provides local limit alarm capability. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 94 ® IntelliPack ++ ® IntelliPack 8400100.qxp 3/20/2006 3:19 PM Page 95 Signal Conditioners n Output (Relay) n Physical n Performance Relay Enclosure n Frequency Input One SPDT electro-mechanical relay. Case: Thermoplastic UL94 V-2 NEMA Type 1 enclosure. Input Types Relay Ratings (CSA ratings) Connectors (Removable Terminal Blocks) TTL, dry contact, open collector NPN/PNP, NAMUR, mag- 25V DC @ 5A. Wire Range: AWG #14-22 (AWG #12 stranded only). netic pickups, proximity sensors. 120/240V AC @ 5A. Printed Circuit Boards Frequency Ranges Relay Time Delay Military grade FR-4 epoxy glass circuit board. 0 to 100Hz Adjustable alarm delay of up to 25 seconds. 0 to 1000Hz Dimensions and Shipping Weight 0 to 50,000Hz. Contact Material 1.05W x 4.68H x 4.35D in. (26.7 x 118.9 x 110.5 mm) Silver-cadmium oxide (AgCdO). 1 pound (0.45 Kg) packed. Pulse Counter Input Range 0 to 65535 pulses. Expected Mechanical Life n Ordering 20 million operations. Minimum Input Pulse Width Information Frequency inputs: 10μS. n Environmental Pulse counting inputs: 5mS. IMPORTANT: All IntelliPacks require initial soft- Ambient Temperature ware configuration (order 800C-SIP). Voltage Ranges Operating: -25 to 70°C (-13 to 158°F). See Note 1 below. Unipolar: 0 to 100V DC. Storage: -40 to 85°C (-40 to 185°F). Bipolar: ±50mV to ±100V peak. 841T-0500 Relative Humidity Zero/Full Scale Adjustment IntelliPack transmitter unit (freq/pulse counter input). 5 to 95%. Zero and span: 100% full range adjustment. 841T-1500 Power Requirements Pulse counting: Up to 65535 spans within range. Same as above, plus an SPDT relay output. 10 to 36V DC. 100mA @ 24V. 160mA @ 15V. 800C-SIP Input Threshold/Hysteresis Isolation (optical) Software Interface Package. Bipolar: 4-way (input/output/relay/power). Only one kit is required for all IntelliPack models. Threshold: 0.01V, typical. 1500V AC for 60 seconds or 250V AC continuous. See diagram on Page 83 for included parts. Hysteresis: ±25mV or ±83mV. Unipolar: 5034-225 Radiated Field Immunity (RFI) Threshold: 1.5V or 5V. USB-to-RS232 adapter. See page 121 for more info. EN61000-4-3, EN50082-1. Hysteresis: ±25mV or ±83mV PS5R-D24 Electromagnetic Field Immunity (EMI) Power supply (24V DC, 2.1A). Input Debounce (Event Counter) Less than ±0.25% of output span effect under the See Power Supplies on Page 199. 0 to 1000mS (configurable in 5mS increments). influence of electromagnetic fields from switching TBK-B01 solenoids, commutator motors, and drill motors. Frequency Excitation Supply Optional terminal block kit, barrier strip style, 2 pcs. Selectable, +8.2V or +12V @ 15mA. Electrical Fast Transient (EFT) (For use with 841T-0500 model.) EN61000-4-4, EN50082-1. Input Impedance TBK-B02 35K ohms, typical. Surge Withstanding Capability (SWC) Optional terminal block kit, barrier strip style, 4 pcs. EN61000-4-5, EN50082-1. (For use with 841T-1500 model with alarm.) Accuracy Input Range Accuracy TBK-S01 Electrostatic Discharge (ESD) 0 to 100Hz ±0.04Hz Optional terminal block kit, spring clamp style, 2 pcs. EN61000-4-2, EN50082-1. 0 to 1000Hz ±0.4Hz (For use with 841T-0500 model.) Radiated Emissions 0 to 50,000Hz ±10Hz TBK-S02 EN50081-1 for Class B equipment. 0 to 65,535 pulses ±1 pulse Optional terminal block kit, spring clamp style, 4 pcs. (For use with 841T-1500 model with alarm.) Approvals n Output (DC V/mA) UL listed (USA, Canada). NOTE 1: To order factory configuration, call Acromag D/A Converter UL3121 - general product safety. for a configuration form which must accompany your 16-bit S-D. order. Also, append “-C” to model number (example: n Configuration 841T-1500-C). 800C-SIP kit is still recommended. Current Output Ranges: 0-1mA, 0-20mA, 4-20mA. Software Configuration Compliance: 10V minimum (500W load). Units are fully programmable via the Windows Accuracy: 0.025% of span. XP/Vista/7 IntelliPack Configuration Program. Configuration downloads from PC through Voltage Output EIA232 serial port using Acromag 800C-SIP kit. Ranges: 0-5V, 0-10V. Compliance: 10mA maximum with short circuit pro- Field Configuration tection. 1 ohm output impedance. Output, zero/full-scale, relay setpoint and deadband are Accuracy: 0.025% of span. configurable via push-buttons and a standard calibrator. Optional terminal blocks: barrier strip (left) and Accuracy (overall input to output) LED Indicators spring clamp (right). Cage clamp terminal is standard. 0.075% of span. LEDs indicate power, status, calibration, and alarm. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 95 (118.9) 4.68 (95.3) 3.75 (59.4) 2.34 8400100.qxp 3/20/2006 3:19 PM Page 120 ® IntelliPack 800 Series Dimensions Acromag RUN "T" RAIL DIN MOUNTING ST DIN EN 50022, 35mm 12 RELAY MODE SET C L RST 1 RST 2 SCREWDRIVER SLOT FOR REMOVAL FROM "T" RAIL R 3.90 1.05 (99.1) (26.7) 4.35 (110.5) NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS) Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 120 ® IntelliPack ® IntelliPack 8400100.qxp 3/20/2006 3:19 PM Page 121 Signal Conditioners Accessories Terminal Blocks Mounting Hardware Power Supplies Barrier strip (left) and spring clamp (right). n Ordering Information See individual I/O modules for compatibility. Barrier Strip Terminal Blocks Wire range: DIN-Rail Mounting 50W Supply AWG #12-26 For your convenience, Acromag offers several Input Power Requirement 85 to 264V AC or 105 to 370V DC mounting accessories to simplify your system installation. Our 19” rack-mount kit provides a Output clean solution for mounting your I/O modules 24V DC, 2.1A (50W) and a power supply. Or you can buy precut DIN n Ordering Information rail strips for mounting on any flat surface. 6-position: L = 1.47 inches (37.7 mm) PS5R-D24 Universal 50W power supply n Ordering Information Wire range: AWG #12-26 20RM-16-DIN See Power Supplies on Page 199 for other models 19" rack-mount kit with DIN rail. and more information. DIN RAIL 3.0 DIN RAIL 16.7 USB / RS232 Adapter DIN rail strip, Type T, 3 inches (75mm) or 16.7 inches (425mm) Length: 3.15 in (8.0 cm) 3-position: L = 0.87 inches (22.3 mm) Height: 0.80 in (2.03 cm) TBK-B01 TBK-B03 Width: 1.75 in (4.44 cm) Terminal block kit, Terminal block kit, Weight: 1.6 oz (45.36 g) two 6-position pieces one 3-position and three 6-position pieces n Ordering TBK-B02 Information Terminal block kit, four 6-position pieces 5034-225 USB-to-RS232 adapter Spring Clamp Terminal Blocks Wire range: AC Current Sensor AWG #12-26 3-position: L = 0.66 inches (16.9 mm) 6-position: L = 1.26 inches (32.3 mm) TBK-S01 TBK-S03 n Ordering Information Terminal block kit, Terminal block kit, 5020-350 two 6-position pieces one 3-position and AC current sensor (See page 205) three 6-position pieces TBK-S02 Terminal block kit, four 6-position pieces Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 121

Related Products

ACROMAG
Intelligent Transmitter, DC Voltage/Current Input Transmitter, DC voltage o...
ACROMAG
Intelligent Transmitter, DC Frequency/Pulse Input Acromag's IntelliPack® se...
ACROMAG
Intelligent Transmitter, Strain Gage / Load Cell Input IntelliPack strain g...
ACROMAG
Transmitter, Current/Millivolt Input, DC or Loop-Powered The TT236 model is...
ACROMAG
Transmitter, Current/Millivolt Input, DC Power The TT336 model is a space-s...
ACROMAG
Transmitter, Voltage Input, DC Power The TT337 model is a space-saving four...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 7.779 seconds.