Signal Conditioners & Converters/Temperature Transmitters

ACROMAG 801T-1500-C

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number 801T-1500-C
Manufacturer ACROMAG
Category Signal Conditioners & Converters »  Temperature Transmitters
Price Request Quote
Lead Time Request Quote

Description

0 to 20mA DC, 0 to 10V DC output
801T:Intelligent Temperature Transmitter,Universal Input (TC/RTD/mV/ohms) Acromag's IntelliPack® series is a family of high-performance, multi-function I/O modules. These transmitters isolate and convert sensor inputs to noise-free, proportional DC current or voltage output signals. An optional relay output adds a local limit alarm function. IntelliPack temperture transmitters feature universal input/output ranges and an intelligent microcontroller to provide extreme flexibility and powerful signal conditioning capabilities. This flexibility enables a single IntelliPack to handle a broad range of applications. As your needs change, you can easily reconfigure the unit for different ranges or functions. Software configuration (Windows XP/Vista®/7) makes setup fast and easy. Push-button field adjustment (no PC required) keeps routine maintenance simple with a conventional calibrator. IntelliPacks are an ideal solution for a broad range of process monitoring and control applications. Once configured, IntelliPacks operate independent of any host computer. Temperature Transmitter; thermocouple, RTD, DC mV, and resistance input; DC voltage or current outputTemperature Transmitter; thermocouple, RTD, DC mV, and resistance input; DC voltage or current output, with factory calibrationTemperature Transmitter; thermocouple, RTD, DC mV, and resistance input; DC voltage or current output; limit alarm with relayTemperature transmitter; thermocouple, RTD, DC mV, and resistance input; DC voltage or current output; limit alarm with relay, with factory calibration

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 801T-1500-C? We can help you find it at a competitive price!

Specifications

Categorization Information Signal Conditioners & Converters
Temperature Transmitters
Universal Temperature Transmitters
IntelliPack 800T Series

Features

  • Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC), 0 to 500 ohms input
  • Mechanical relay (25V @ 5A) alarm
  • 10-36V DC power
  • Software configured
  • Performs linearization, square root extraction, and optional limit alarm functions
  • Temperature transmitter with universal input/output capabilities
  • Advanced internal microcontroller
  • Windows® software configuration
  • User-programmable input/output ranges
  • Push button field calibration
  • High-resolution Sigma-Delta A/D converter
  • Intelligent signal processing functions (linearization, averaging, square root)
  • Limit alarm capability with relay output option
  • Self-diagnostics
  • 4-way isolation
  • Input excitation supply for a 2-wire transmitter or relay input
  • 25 to 70°C (-13 to 158°F) operation
  • All IntelliPacks require initial software configuration (order 800C-SIP).

Datasheet

Download "IntelliPack_Overview_0.pdf" (239 KiB)

Extracted Text

8400100.qxp 3/20/2006 3:18 PM Page 90 ® IntelliPack 800 Series Transmitter w/alarm Alarm N.O. COM N.C. SPDT Relay Signal (801T-1500) Conditioning and Isolation Input Output Current Intelligent DC Voltage or I+ Out Transfer Current Ouput JMP Voltage Out Functions V+ R R L L RTN Power DC- 10 - 36V DC DC+ Power n Description n Performance 801T These transmitters isolate and convert sensor n General Input Transmitters inputs to noise-free, proportional DC current or Analog to Digital Converter (ADC) voltage output signals. An optional relay output 16-bit S-D A/D converter. adds a local limit alarm function. Thermocouple, Resolution RTD, Millivolt, and ±0.005% of span or 0.1°C. Each unit offers a selection of input and output Resistance Input ranges, as well as several signal conditioning Ambient Temperature Effect options. This flexibility enables a single IntelliPack Better than ±0.005% of input span per °C or ±1μV, Models whichever is greater. to handle a broad range of applications. As your 801T-0500: Universal temperature transmitter needs change, you can easily reconfigure the Noise Rejection 801T-1500: Transmitter with limit alarm unit for different ranges or functions. Normal Mode: Better than 40dB @ 60Hz. Common Mode: Better than 130dB @ 60Hz. Input Ranges Setup is very easy. IntelliPack modules are quickly Input Response Time (for input step change) TC types: J, K, T, R, S, E, B, N configured with the user-friendly Windows soft- Less than 200mS typical Millivolt: ±15.625mV to ±1.0V DC ware program. Field adjustments are simple with to 98% of final output value. RTD: 100 ohm Pt, 120 ohm Ni, 10 ohm Cu the module’s front-panel push-buttons and status Input Overvoltage Protection Resistance: 0 to 500 ohms LEDs. Once configured, IntelliPacks operate Bipolar Transient Voltage Suppressors (TVS). independent of any host computer. Output Ranges n Thermocouple Input 0 to 1mA, 0 to 20mA, 4 to 20mA DC n Special Features Thermocouple Input Ranges 0 to 5V, 0 to 10V DC Thermocouple type user configured. Signal n High-resolution Sigma-Delta A/D converter linearization, cold-junction compensation, and open delivers high accuracy with low noise. Limit Alarm circuit or lead break detection are included. SPDT electro-mechanical relay (-1500 unit only) TC °C Range (°F Range) Accuracy n Advanced microcontroller provides intelligent J -210 to 760°C (-346 to 1400°F) ±0.5°C signal processing power for linearization, Power Requirement K -200 to 1372°C (-328 to 2502°F) ±0.5°C averaging, and square root computations. T -260 to 400°C (-436 to 752°F) ±0.5°C 10 to 36V DC R -50 to 1768°C (-58 to 3214°F) ±1.0°C n Windows XP/Vista/7 software S -50 to 1768°C (-58 to 3214°F) ±1.0°C Approvals configuration speeds setup and replacement. E -200 to 1000°C (-328 to 1832°F) ±0.5°C CE marked. UL, cUL listed. B 260 to 1820°C (500 to 3308°F) ±1.0°C n Multi-purpose inputs and outputs reduce N -230 to 1300°C (-382 to 2372°F) ±1.0°C spare stock requirements. Thermocouple Break Detection n Relay output option provides local TC sensor failure can be configured for either upscale limit alarm capability. or downscale. 4-Wire RTD 4-Wire RTD TC Input 2-Wire RTD 3-Wire RTD (Kelvin) w/Loop Millivolt Resistance Comp. + IN+ IN+ IN+ IN+ IN+ IN+ IN+ IN- IN- IN- IN- IN- IN- IN- EXC+ EXC+ EXC+ EXC+ EXC+ EXC+ EXC+ RTN RTN RTN RTN RTN RTN RTN Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 90 ® IntelliPack + + ® IntelliPack 8400100.qxp 3/20/2006 3:18 PM Page 91 Signal Conditioners n RTD Input n Output (Relay) n Physical RTD Input Ranges Relay Enclosure 100 ohm Platinum, 120 ohm Nickel, or One SPDT electro-mechanical relay. Case: Self-extinguishing NYLON type 6.6 polyamide ther- 10 ohm Copper; user-configured. moplastic UL94 V-2 NEMA Type 1 enclosure. Relay Ratings (CSA ratings) RTD °C Range (°F Range) Accuracy 25V DC @ 5A. Connectors (Removable Terminal Blocks) 1 Pt -200 to 850°C (-328 to 1562°F) ±0.25°C 120/240V AC @ 5A. Wire Range: AWG #14-22 (AWG #12 stranded only). 2 Pt -200 to 850°C (-328 to 1562°F) ±0.25°C Relay Time Delay Printed Circuit Boards Ni -80 to 320°C (-112 to 608°F) ±0.25°C Adjustable alarm delay of up to 25 seconds. Military grade FR-4 epoxy glass circuit board. Cu -200 to 260°C (-328 to 500°F) ±1.00°C Alpha: Pt1 (a = 1.3850), Pt2 (a = 1.3911), Contact Material Dimensions Ni (a = 1.6720), Cu (a = 1.4272). Silver-cadmium oxide (AgCdO). 1.05W x 4.68H x 4.35D inches. 26.7W x 118.9H x 110.5D millimeters. 2, 3, or 4-wire configurations supported. Module pro- Expected Mechanical Life vides sensor excitation, linearization, lead-wire com- 20 million operations. Shipping Weight pensation, and sensor break detection. 1 pound (0.45 Kg) packed. n Environmental RTD Excitation Current 1mA DC typical, all types. Ambient Temperature Operating: -25 to 70°C (-13 to 158°F). n Ordering RTD Lead-Wire Compensation Storage: -40 to 85°C (-40 to 185°F). 25 ohms per lead. Information Relative Humidity RTD Break Detection IMPORTANT: All IntelliPacks require initial 5 to 95%. RTD sensor failure can be configured for either upscale software configuration (order 800C-SIP). or downscale. Power Requirements See Note 1 below. 10 to 36V DC. 75mA @ 24V. 120mA @ 15V. n Millivolt Input 801T-0500 Isolation (optical) DC Millivolt/Voltage Input Ranges IntelliPack transmitter (TC/RTD/mV/resistance input). 4-way (input/output/relay/power). ±1.0V ±125mV ±31.25mV 801T-1500 1500V AC for 60 seconds or 250V AC continuous. ±500mV ±62.5mV ±15.625mV Same as above, plus an SPDT relay output. ±250mV Radiated Field Immunity (RFI) 800C-SIP EN61000-4-3, EN50082-1. Millivolt Accuracy Software Interface Package. Better than ±0.05% of input span. Only one kit is required for all IntelliPack models. Electromagnetic Field Immunity (EMI) See diagram on Page 83 for included parts. Less than ±0.25% of output span effect under the n Resistance Input influence of electromagnetic fields from switching 5034-225 Resistance Input Range solenoids, commutator motors, and drill motors. USB-to-RS232 adapter. See page 121 for more info. 0 to 500 ohms. PS5R-D24 Electrical Fast Transient (EFT) Power supply (24V DC, 2.1A). Resistance Accuracy EN61000-4-4, EN50082-1. See Power Supplies on Page 199. ±0.05 ohms. Surge Withstanding Capability (SWC) TBK-B01 EN61000-4-5, EN50082-1. n Output (DC V/mA) Optional terminal block kit, barrier strip style, 2 pcs. (Does not include terminal block for input wiring.) D/A Converter Electrostatic Discharge (ESD) 16-bit S-D. EN61000-4-2, EN50082-1. TBK-S01 Optional terminal block kit, spring clamp style, 2 pcs. Radiated Emissions Current Output (Does not include terminal block for input wiring.) EN50081-1 for Class B equipment. Ranges: 0-1mA, 0-20mA, 4-20mA. Compliance: 10V minimum (500 ohm load). Approvals NOTE 1: To order factory configuration, call Acromag Accuracy: 0.025% of span. CE, UL listed (USA, Canada). for a configuration form which must accompany your UL3121 - general product safety. Voltage Output order. Also, append “-C” to model number (example: Ranges: 0-5V, 0-10V. 801T-1500-C). 800C-SIP kit is still recommended. n Configuration Compliance: 10mA maximum with short circuit pro- tection. 1 ohm output impedance. Software Configuration Accuracy: 0.025% of span. Units are fully programmable via the Windows XP/Vista,7 IntelliPack Configuration Accuracy (overall input to output) Program. Configuration downloads from PC through 0.075% of span. EIA232 serial port using Acromag 800C-SIP kit. Field Configuration Output, zero/full-scale, relay setpoint and deadband are configurable via push-buttons and a standard calibrator. Optional terminal blocks: barrier strip (left) and LED Indicators spring clamp (right). Cage clamp terminal is standard. LEDs indicate power, status, calibration, and alarm. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 91 (118.9) 4.68 (95.3) 3.75 (59.4) 2.34 8400100.qxp 3/20/2006 3:19 PM Page 120 ® IntelliPack 800 Series Dimensions Acromag RUN "T" RAIL DIN MOUNTING ST DIN EN 50022, 35mm 12 RELAY MODE SET C L RST 1 RST 2 SCREWDRIVER SLOT FOR REMOVAL FROM "T" RAIL R 3.90 1.05 (99.1) (26.7) 4.35 (110.5) NOTE: ALL DIMENSION ARE IN INCHES (MILLIMETERS) Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 120 ® IntelliPack ® IntelliPack 8400100.qxp 3/20/2006 3:19 PM Page 121 Signal Conditioners Accessories Terminal Blocks Mounting Hardware Power Supplies Barrier strip (left) and spring clamp (right). n Ordering Information See individual I/O modules for compatibility. Barrier Strip Terminal Blocks Wire range: DIN-Rail Mounting 50W Supply AWG #12-26 For your convenience, Acromag offers several Input Power Requirement 85 to 264V AC or 105 to 370V DC mounting accessories to simplify your system installation. Our 19” rack-mount kit provides a Output clean solution for mounting your I/O modules 24V DC, 2.1A (50W) and a power supply. Or you can buy precut DIN n Ordering Information rail strips for mounting on any flat surface. 6-position: L = 1.47 inches (37.7 mm) PS5R-D24 Universal 50W power supply n Ordering Information Wire range: AWG #12-26 20RM-16-DIN See Power Supplies on Page 199 for other models 19" rack-mount kit with DIN rail. and more information. DIN RAIL 3.0 DIN RAIL 16.7 USB / RS232 Adapter DIN rail strip, Type T, 3 inches (75mm) or 16.7 inches (425mm) Length: 3.15 in (8.0 cm) 3-position: L = 0.87 inches (22.3 mm) Height: 0.80 in (2.03 cm) TBK-B01 TBK-B03 Width: 1.75 in (4.44 cm) Terminal block kit, Terminal block kit, Weight: 1.6 oz (45.36 g) two 6-position pieces one 3-position and three 6-position pieces n Ordering TBK-B02 Information Terminal block kit, four 6-position pieces 5034-225 USB-to-RS232 adapter Spring Clamp Terminal Blocks Wire range: AC Current Sensor AWG #12-26 3-position: L = 0.66 inches (16.9 mm) 6-position: L = 1.26 inches (32.3 mm) TBK-S01 TBK-S03 n Ordering Information Terminal block kit, Terminal block kit, 5020-350 two 6-position pieces one 3-position and AC current sensor (See page 205) three 6-position pieces TBK-S02 Terminal block kit, four 6-position pieces Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 121

Related Products

ACROMAG
0 to 20mA DC, 0 to 10V DC output 801T:Intelligent Temperature Transmitter,U...
ACROMAG
0 to 20mA DC, 0 to 10V DC output 801T:Intelligent Temperature Transmitter,U...
ACROMAG
Transmitter, RTD Input, Loop-Powered The ST131 is a low-cost two-wire trans...
ACROMAG
Transmitter, Thermocouple Input, Loop-Powered The ST133 is a low-cost two-w...
ACROMAG
Transmitter, RTD Input, Loop Power The TT231 model is a space-saving two-wi...
ACROMAG
Transmitter, Thermocouple/Millivolt Input, DC Local/Bus Power The TT333 mod...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.062 seconds.