Part Number 801A-0100
Manufacturer ACROMAG
Category Signal Conditioners & Converters »  Limit Alarms
Price Request Quote
Lead Time Request Quote

Description

801A: Intelligent Alarm, Universal TC/RTD/mV Input
Acromag's IntelliPack® series is a family of high-performance, multi-function I/O modules. IntelliPacks feature universal input/output ranges and an intelligent microcontroller to provide extremely flexibility and powerful signal conditioning capabilities. As your needs change, you can easily reconfigure the unit for different ranges or functions. Alarm functions available on all models include on/off controller, limit alarm, window alarm, deviation alarm, rate-of-change alarm, and peak/valley detection. Software configuration (Windows XP/Vista®/7) makes setup fast and easy. Push-button field adjustment (no PC required) keeps routine maintenance simple with a conventional calibrator. Once configured, IntelliPacks operate independent of any host computer. IntelliPacks are an ideal solution for a broad range of process monitoring and control applications. Alarm; thermocouple, RTD, mV, or ohms input; DPDT relay, with factory calibrationAlarm; thermocouple, RTD, mV, or ohms input; two SPDT relaysAlarm; thermocouple, RTD, mV, or ohms input; two SPDT relays; with factory calibrationAlarm; thermocouple, RTD, mV, or ohms input; DPDT relay

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 801A-0100? We can help you find it at a competitive price!

Specifications

Categorization Information Signal Conditioners & Converters
Limit Alarms
Universal Input
IntelliPack 800A Series

Features

  • Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt (±100mV DC) input
  • Single or dual mechanical relay alarms
  • 10-36V DC power
  • Software configured
  • Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection)
  • On/off controller capability
  • Integrated microcontroller performs intelligent signal processing for advanced alarm functions.
  • Windows XP/Vista/7 software configuration speeds setup and replacement.
  • Push-button reprogrammability facilitates changes in the field without a host PC.
  • Multi-purpose inputs accept numerous ranges to reduce spare stock requirements.
  • High-resolution Sigma-Delta A/D converter delivers high accuracy with low noise.
  • Input excitation supply on each input provides power for a two-wire transmitter.
  • Dual alarm operation lets you perform two alarm functions at the same time.
  • -25 to 70°C (-13 to 158°F) operation
  • All IntelliPacks require initial software configuration (order 800C-SIP).

Datasheet

Download "IntelliPack_Overview_0.pdf" (211 KiB)

Extracted Text

Application Notes Using Acromag’s AC current sensor Model 5020-350 Several Acromag transmitters with DC current input can be used used in conjunction with an external AC Current Sensor to precondition an AC current input signal. This sensor is a highly accurate toroidal instrument transformer that converts an AC current signal to a safe, low- level, DC milliampere signal (0 to 11.17mA). The transmitters only accept the isolated low- level signal produced by the AC current sensing transformer and cannot be connected directly to Acromag's Flat Pack transmitters are shown with the AC current sensor toroidal transformer. the source of AC power without damage or safety risk. The AC Current Sensor is fully insu- The output wires of the sensor are polarized: the Sensor lated and designed for mounting near the source Primary AC Current Sensor Output Red wire is (+) plus and the Black wire is (-) of the AC current. The input AC current range is Turns Input Range (red/black wires) minus. Normally, these output wires are a simple function of the number of turns placed 1 0 to 20 Amps AC 0 to 11.17mA DC attached to one end of a cable (user supplied) on the AC Current Sensor (see the table below). 2 0 to 10 Amps AC 0 to 11.17mA DC and the other end connects to the transmitter's The benefits to using an external sensor (external 4 0 to 5 Amps AC 0 to 11.17mA DC input. Connect the Current Sensor output leads from the transmitter) include the following: to the transmitter input by connecting Red (+) to 10 0 to 2 Amps AC 0 to 11.17mA DC Low losses: the transmitter's plus (+) terminal, and Black (-) 20 0 to 1 Amps AC 0 to 11.17mA DC It is not practical to run AC currents over long to the transmitter's minus (-) terminal. Proper distances because of significant resistance volt- polarity must be observed. The AC Current Sensor is isolated and can be age drops at high currents. The low-level DC used in AC circuits up to 250V AC, 50 or 60 Hz. milliampere signal output from the AC Current WARNING: It is designed to be mounted at the source of the Sensor can be transmitted safely over long dis- The input to the module can only come AC current to be measured. The transmitter can tances, allowing the transmitter to be remotely from the AC Current Sensor output wires be located remotely from the AC signal and located from the AC power wiring. (red/black). If AC current is directly attached wired using small gauge wire. The sensor's out- to the transmitter's input terminals, the Safety: put wires can be shorted, open-circuited, or transmitter will be destroyed and safety The AC Current Sensor's output leads can be removed from the transmitter's input terminals, compromised. open or short circuited and these conditions without hazard to personnel or the AC Current do not affect the AC current loop or cause Sensor. For most applications, it is recommended that damage to the sensor. Likewise, the wires the minus (-) transmitter input terminal be con- connecting the AC Current Sensor to the DANGER: nected to an earth ground. The connections transmitter can be easily removed from the If the AC Current Sensor is used with an AC between the AC Current Sensor would be float- transmitter's input terminals without concern Current Transformer (C.T.), disconnect power ing if not grounded. Grounding eliminates the or hazard. to the C.T., or short the output of the C.T., risk of high common-mode voltages from show- before removing the wire going through the ing up on the wires and reduces noise pickup. Ease of Calibration: AC Current Sensor. If this is not done, an The AC current input range can be easily open circuited C.T. will generate high volt- Supported Products scaled in the field by simply changing the ages (hazardous) and possible C.T. damage.IntelliPack Series Transmitters and Alarms number of primary turns at the sensor, with no additional calibration required. That is, the610T Series Isolated Transmitters AC current input span is a simple function of ACR Series Isolated Transmitters the number of primary turns placed on the AC Current Sensor and sensor/transmitterFlat Pack 250T/350T/450T Series Transmitters calibration is not affected by this. Refer to and 361A/461A Series Alarms Applications "A" & "B" of the diagrams on ® SmartPack Series LONWORKS I/O Modules the next page. Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 189 Application Notes Dimensions and Electrical Connections Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 190 Application Notes Application Examples Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 191

Related Products

ACROMAG
Limit Alarm, DC Current Input, Loop-Powered The 260A accepts a 4 to 20mA in...
ACROMAG
801A: Intelligent Alarm, Universal TC/RTD/mV Input Acromag's IntelliPack® s...
ACROMAG
801A: Intelligent Alarm, Universal TC/RTD/mV Input Acromag's IntelliPack® s...
ACROMAG
Intelligent Alarm, Dual Thermocouple/mV Input IntelliPack alarms compare in...
ACROMAG
Intelligent Alarm, Dual RTD Input IntelliPack alarms compare inputs against...
ACROMAG
DC Current/Voltage Modbus-RTU Input Module with Limit Alarms 913MB: 4 curre...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.04 seconds.