430i: Isolator, AC-Powered
Series 430i isolators provide 3-way isolation and do not require recalibration for different loads. The 430i accepts a 4 to 20mA process current input and provide a 3-way isolated process current output signal. These isolators use transformer isolation to effectively break the electrical path between the transmitted signal, receiving device, and power. This eliminates ground loops, reduces noise, and helps protect sensitive instruments from transients for more accurate and reliable measurements. The 430i isolators are also extremely easy to use. Advanced circuitry eliminates the need to recalibrate as loads change and allows us to provide factory calibration regardless of the load. And, for highly reliable field operation, they withstand extreme ambient temperatures and have excellent temperature coefficients.Isolator, Single-channel: 4 to 20mA DC input; 4 to 20mA DC output; 115V AC-power.

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 430I-C1-Y-1-DIN-NCR? We can help you find it at a competitive price!

Specifications

Categorization Information 4-20mA Isolators & Splitters
4-20mA Isolators
4-Wire AC/DC-powered Isolators
Flat Pack Series

Features

  • 4 to 20mA DC input
  • 4 to 20mA DC output
  • 115V AC or 230V AC power
  • Three-way isolation
  • Zero and span adjustment enable precise calibration
  • 3-way isolation; input, output, and power circuits are isolated from each other.
  • 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops.
  • Excellent accuracy and stability ensure reliable measurements in harsh industrial environments
  • RFI and EMI resistance minimize the effects of environmental noise
  • Factory calibration is provided standard
  • Calibration is independent of the load to eliminate load compensation adjustments
  • Low input burden (1.3V typical), independent of load, helps prevent overloading of the loop
  • High load compliance drives output load resistances up to 1050 ohms independent of supply voltage
  • 25mS response time delivers fast updates to monitoring and control systems.
  • Zero and span adjustment enable precise calibration.
  • -13 to 185°F (-25 to 85°C) operation

Datasheet

Download "330i_430i%20Isolated%20Transmitters.pdf" (101 KiB)

Extracted Text

8400100.qxp 3/20/2006 3:21 PM Page 154 Flat Pack Series 330i Isolator Diagram Isolated Transmitters PLC / DCS 330i + + IN OUT 4-20mA – – 4-20mA Rs Source 3-way Isolation 10-36V DC 430i Isolator Diagram PLC / DCS 430i + + 4-20mA IN OUT – – 4-20mA Rs Source 3-way Isolation 115/230V AC 330i and 430i Signal Isolators n Description n Special Features Series 330i and 430i isolators provide 3-way n 3-way isolation; input, output, and power DC Current Input isolation and do not require recalibration for circuits are isolated from each other. different loads. n 1500V AC peak isolation (250V AC or 354V Models Both the 330i and 430i accept a 4 to 20mA DC continuous) prevents ground loops. 330i: DC-powered transmitter series process current input and provide a 3-way n Excellent accuracy and stability ensure reliable 430i: AC-powered transmitter series isolated process current output signal. measurements in harsh industrial environments Input Range These isolators use transformer isolation to n RFI and EMI resistance minimize the effects of n 4 to 20mA DC effectively break the electrical path between the environmental noise transmitted signal, receiving device, and power. Output Range This eliminates ground loops, reduces noise, and n Factory calibration is provided standard n 4 to 20mA DC helps protect sensitive instruments from transients n Calibration is independent of the load to for more accurate and reliable measurements. eliminate load compensation adjustments Power Requirements The 330i and 430i are also extremely easy to use. n 330i: 10 to 36V DC n Wide power supply range on 330i handles Advanced circuitry eliminates the need to recali- 85mA with 15V supply, 55mA at 24V more applications to reduce inventory stock brate as loads change and allows us to provide n 430i: factory calibration regardless of the load. And, n DC power used with 330i carry lower voltages 115V AC @ 0.040A for highly reliable field operation, they withstand and do not require expensive conduit for safer 230V AC @ 0.020A extreme ambient temperatures and have excel- and easier installation. lent temperature coefficients. n Low input burden (1.3V typical), independent of load, helps prevent overloading of the loop n High load compliance drives output load resistances up to 1050 ohms independent of supply voltage n 25mS response time delivers fast updates to monitoring and control systems. n Zero and span adjustment enable precise calibration. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 154 Flat Pack Flat Pack 8400100.qxp 3/20/2006 3:21 PM Page 155 Isolated Transmitters n Environmental n Performance n Ordering Ambient temperature range Reference test conditions Information -13 to 185°F (-25 to 85°C) Input/Output current: 4 to 20mA; output load 250 Ambient temperature effect ohms; 25°C ambient; 15V DC or 115V AC supply. Isolators Less than ±0.003% of output span per °F (±0.005% 330i-C1-Y-DIN-NCR per °C) over the ambient temperature range for refer- n Input Single-channel isolator unit, DC-powered. ence test conditions. This specification includes the Input 430i-C1-Y-1-DIN-NCR combined effects of zero and span over temperature. 4 to 20mA DC, with an input drop less than 1.5V DC Single-channel isolator unit, 115V AC-powered. (75 ohms) at full-scale. IMPORTANT: Input current Isolation must not exceed 100mA or damage to the unit may 430i-C1-Y-2-DIN-NCR Three-way isolation between input, output, and power occur. Single-channel isolator unit, 230V AC-powered. circuits for common mode voltages up to 250V AC, or 354V DC off ground, on a continuous basis (withstand Zero and span Accessories 1500V AC dielectric strength test for sixty seconds Zero and span trim adjustments utilize 15-turn without breakdown). Power supplies potentiometers accessible on front of the unit. See Power Supplies on Page 199. Noise rejection n Output Normal Mode: -6 dB at 60Hz, typical, 500 ohm load. DIN RAIL 3.0 Output DIN RAIL 16.7 RFI resistance 4 to 20mA DC RLOAD = 0 to 1050 ohms. DIN rail strip, Type T, 3 inches (75mm) or Less than ±0.5%, of output span with RFI field Output limiting 16.7 inches (425mm) strengths of up to 10V/meter at frequencies of 27, Output current limited to less than 28mA, nominal. 151 and 467 MHz. 20RM-16-DIN Output ripple 19" rack-mount kit with DIN rail. Holds ten 330i or EMI resistance Less than ±0.1% of maximum output span. 430i transmitters. Less than ±0.25% of output span effect with switch- Accuracy ing solenoids or commutator motors. 350T-N4-WM Better than ±0.1% of output span. Error includes the NEMA 4 water-tight enclosure, wall-mount. Surge withstand capability (SWC) combined effects of isolator repeatability, hysteresis, Holds one 330i/430i transmitter. Input/Output terminations rated per ANSI/IEEE C37.90- terminal point linearity and adjustment resolution. 1978. Unit is tested to a standardized test waveform 350T-N12-WM Does not include sensor error. that is representative of surges (high frequency transient NEMA 12 oil-tight enclosure, wall-mount. Bandwidth electrical interference), observed in actual installations. Holds one 330i/430i transmitter. -3dB at 50Hz, typical, with 500 ohm load. n Physical Response time Construction For a step input, the output reaches 98% of output Circuit boards: Military grade FR-4 epoxy glass. span in 25mS, typical, with a 500 ohm load. Terminals: Compression type, 14 AWG max. Response time will vary with load resistance. Case: Self-extinguishing NYLON Type 6.6 polyamide thermoplastic UL94V-2, color black. General Purpose, n Power NEMA Type 1 enclosure. Power (330i) Circuit board coating: Fungus resistant acrylic 10V to 36V DC, current draw is a function of supply conformal coat. voltage (refer to table below) Mounting position: Position insensitive. Supply Supply Current At Current Voltage at 20mA Output Limit 10V 135mA 200mA 12V 105mA 145mA 15V85mA 110mA 24V55mA 70mA 36V 45mA 50mA Power (430i) -1: 115V AC ±10%, 50 to 60Hz, 0.040A max. -2: 230V AC ±10%, 50 to 60Hz, 0.020A max. Power supply effect 330i: Less than ±0.001% of output span per volt for rated supply variations. 430i: Less than ±0.01% of output span for rated supply variations. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 155

Related Products

ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
633T: Signal Splitter, AC/DC-Powered These units receive 4-20mA process cur...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 1.478 seconds.