ACROMAG 340I-C1-Y-DIN-NCR

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number 340I-C1-Y-DIN-NCR
Manufacturer ACROMAG
Category Isolators & Splitters
Price Request Quote
Lead Time Request Quote

Description

340i: Isolator, DC-Powered
The 340i accepts a process current input and provides an isolated 4 to 20mA process current output signal. These isolators use transformer isolation to effectively break the electrical path between the transmitted signal and the receiving device. This eliminates ground loops, reduces noise, and helps protect against transients for more accurate and reliable measurements.Isolator, single-channel: 4 to 20mA DC input; 4 to 20mA DC output; 10 to 36V DC @ 30mA power.

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

IPC Station is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 340I-C1-Y-DIN-NCR? We can help you find it at a competitive price!

Specifications

Categorization Information 4-20mA Isolators & Splitters
4-20mA Isolators
3-Wire DC-Powered Isolators
Flat Pack Series

Features

  • 4 to 20mA DC inoput
  • 4 to 20mA DC output
  • 10-36V DC power
  • 1500 AC peak isolation prevents ground loops
  • Calibration is independent of the load to eliminate load compensation adjustments
  • Excellent accuracy and stability ensure reliable measurements in harsh industrial environments.
  • 1500V AC peak isolation (250V AC or 354V DC continuous) prevents ground loops.
  • Zero and span adjustment enable precise calibration.
  • RFI and EMI resistance minimize the effects of environmental noise.
  • Low power consumption helps prevent expensive upgrades to larger power supplies.
  • 25mS response time delivers fast updates to monitoring and control systems.
  • Compact, 1-inch wide housing uses less space for easier installation in control panels.

Datasheet

Download "340i%20Isolated%20Transmitters.pdf" (99 KiB)

Extracted Text

8400100.qxp 3/20/2006 3:21 PM Page 152 Flat Pack Series 340i Isolator Diagram Isolated Transmitters PLC / DCS P + P 340i PWR + – IN + 24V DC OUT 4-20mA RLOAD Input – L – Isolation n Description n Special Features The 340i accepts a process current input and n Excellent accuracy and stability ensure reliable provides an isolated 4 to 20mA process current measurements in harsh industrial environments. output signal. n 1500V AC peak isolation (250V AC or 354V These isolators use transformer isolation to DC continuous) prevents ground loops. effectively break the electrical path between n Calibration is independent of the load to elimi- the transmitted signal and the receiving device. 340i Isolators nate load compensation adjustments This eliminates ground loops, reduces noise, and helps protect against transients for more n Zero and span adjustment enable precise DC Current Input accurate and reliable measurements. calibration. Input Range This product is also extremely easy to install. n RFI and EMI resistance minimize the effects of n 4 to 20mA DC All units are factory calibrated to eliminate any environmental noise. need for load trim adjustments. Also, up to n Low power consumption helps prevent Output Range eight isolators at a location can share a single expensive upgrades to larger power supplies. n 4 to 20mA DC Acromag 35PS power supply for a more convenient and cost-effective solution. n 25mS response time delivers fast updates to Power Requirement monitoring and control systems. n 10 to 36V DC @ 30mA n Compact, 1-inch wide housing uses less space for easier installation in control panels. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 152 Flat Pack Flat Pack 8400100.qxp 3/20/2006 3:21 PM Page 153 Isolated Transmitters n Environmental n Performance n Ordering Ambient temperature range Reference test conditions Information Operating: -13 to 185°F (-25 to 85°C). Input/Output current: 4 to 20mA; output load 250 Storage: -40 to 185°F (-40 to 85°C). ohms; 77°F (25°C); 15V DC supply. Isolator Ambient temperature effect 340i-C1-Y-DIN-NCR Less than ±0.003% of output span per °F (±0.005% n Input Single-channel 4-20mA isolator. per °C) over the ambient temperature range for refer- Input ence test conditions. This specification includes the 4 to 20mA DC, input drop less than 1.5V at full-scale. Accessories combined effects of zero and span over temperature. Input current must not exceed 100mA. Power supplies Isolation Zero and span See Power Supplies on Page 199. The input circuit is electrically isolated from the output The Zero and Span trim adjustments utilize 15-turn DIN RAIL 3.0 and power circuits, allowing the input to operate at potentiometers which are accessible from the front of DIN RAIL 16.7 up to 250V AC, or 354V DC off ground, on a continu- the unit. Isolator is DIN-rail mounted. DIN rail strip, Type T, 3 inches (75mm) or ous basis (will withstand 1500V AC dielectric strength 16.7 inches (425mm) n Output test for one minute without breakdown). Complies Output with test requirements outlined in ANSI C39.5-1974 20RM-16-DIN 4 to 20mA DC. for the voltage rating specified. 19" rack-mount kit with DIN rail. Holds sixteen 340i The output shares a common with the power supply. transmitters. Noise rejection NOTE: Voltage output is not available on this unit, use Common mode: -6 dB at 60Hz, typical, 500 ohm load. 350T-N4-WM Model 350T on Page 144 if this is a requirement. NEMA 4 water-tight enclosure, wall-mount. RFI resistance Holds two 340i transmitters. Load resistance range equation Less than ±0.5%, of output span with RFI field RLOAD MAX = (Min. VDC supply - 5.0V) / 0.02A strengths of up to 10V/meter at frequencies of 27, 350T-N12-WM At 10.0V DC supply, RLOAD = 0 to 250 ohms 151 and 467 MHz. NEMA 12 oil-tight enclosure, wall-mount. At 15.0V DC supply, RLOAD = 0 to 500 ohms Holds two 340i transmitters. EMI resistance At 24.0V DC supply, RLOAD = 0 to 950 ohms Less than ±0.25% of output span effect with switch- Output limiting ing solenoids or commutator motors. 135% of full scale output, nominal. Surge withstand capability (SWC) Output ripple Input/Output terminations rated per ANSI/IEEE C37.90- Less than ±0.1% of maximum output span. 1978. Unit is tested to a standardized test waveform that is representative of surges (high frequency transient Bandwidth electrical interference), observed in actual installations. -3dB at 50Hz, typical, with 500 ohm load. Response time n Physical For a step input, the output reaches 98% of output Construction span in 25mS, typical, 500 ohm load. Circuit boards: Military grade FR-4 epoxy glass. Accuracy Terminals: Compression type, 14 AWG max. Better than ±0.1% of output span. Error includes the Case: Self-extinguishing NYLON Type 6.6 polyamide combined effects of isolator repeatability, hysteresis, thermoplastic UL94V-2, color black. General Purpose, terminal point linearity and adjustment resolution. NEMA Type 1 enclosure. Does not include sensor error. Circuit board coating: Fungus resistant acrylic confor- mal coat. n Power Mounting position: Position insensitive. Power 10.0V to 36.0V DC, 30mA at full scale, 35mA at limit. The external DC power supply is connected between the output (P) and (-) terminals. The current specified is for rated supply inputs and full scale output. Diode on isolator provides reverse polarity protection. Note: Do not exceed 36V DC peak, to avoid damage to the isolator. Power supply effect DC Volts: Less than ±0.001% of output span per volt. 60/120Hz Ripple: Less than ±0.01% of span per volt peak to peak of power supply ripple. Tel: 248-295-0880 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 153

Related Products

ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
270i: Isolator, Input Loop Power The 270i accepts a process current input a...
ACROMAG
USB-Isolator This compact, industrial-grade isolator provides a high-voltag...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on IPC Station are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

IPC Station is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.036 seconds.