PEPPERL+FUCHS 106446
Specifications
Part Number
106446
Product Series
NJ
Type of Sensor
Inductive
Size
18mm
Normally Open or Closed
Normally Closed (NC)
Voltage
NAMUR
NPN or PNP
See Spec or N/A
Shielded/Unshielded
Unshielded - Non-Flush
Connection
Cable
Material
See Spec
Ratings
See Spec
Weight - lbs.
0.0800
Base Unit of Measure
Each
Categorization Information
Proximity Sensors
Inductive Proximity Sensor, 18mm, NAMUR, NC,-106446
Datasheet
Extracted Text
Inductive sensor NJ5-18GK-N-5M Technical Data General specifications Switching element function NAMUR, NC Rated operating distance s 5 mm n Installation flush Output polarity NAMUR Assured operating distance s 0 ... 4.05 mm a Reduction factor r 0.4 Al Reduction factor r 0.3 Cu Reduction factor r 0.85 304 Nominal ratings Nominal voltage U 8 V o Switching frequency f 0 ... 500 Hz Hysteresis Htyp. % Current consumption ≥ 3 mA Measuring plate not detected ≤ 1 mA Measuring plate detected Ambient conditions Ambient temperature -25 ... 100 °C (-13 ... 212 °F) Mechanical specifications 0102 Connection type cable PVC , 5 m 2 Core cross-section 0.75 mm Housing material PBT/PPS Sensing face PBT Degree of protection IP66 / IP68 General information Model Number Use in the hazardous area see instruction manuals 2G; 1D Category NJ5-18GK-N-5M Compliance with standards and directives Standard conformity Features EN 60947-5-6:2000 NAMUR Comfort series IEC 60947-5-6:1999 EN 60947-5-2:2007 Standards 5 mm flush IEC 60947-5-2:2007 Usable up to SIL2 acc. to IEC 61508 Approvals and certificates FM approval Accessories 116-0165F Control drawing BF 18 UL approval cULus Listed, General Purpose Mounting flange, 18 mm CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated ≤36 V Dimensions M18 x 1 24 Electrical Connection BN L+ BU L- Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 1 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com Release date: 2015-05-04 16:26 Date of issue: 2015-05-04 106446_eng.xml 44 1 35.5 39 Inductive sensor NJ5-18GK-N-5M ATEX 2G Instruction Manual electrical apparatus for hazardous areas Device category 2G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 00 ATEX 2048 X CE marking 0102 ATEX marking ¬ II 2G Ex ia IIC T6…T1 Gb Directive conformity 94/9/EG Standards EN 60079-0:2012, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions Appropriate type NJ 5-18GK-N... Effective internal capacitance C ≤ 70 nF ; a cable length of 10 m is considered. i Effective internal inductance L ≤ 50 µH ; a cable length of 10 m is considered. i General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive 94/9/EG and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 °C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permis- sible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appro- priate related apparatus and according to the proof of intrinsic safety. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions When used in the temperature range below -20 °C the sensor should be protected Protection from mechanical danger from knocks by the provision of an additional housing. Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 2 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com Release date: 2015-05-04 16:26 Date of issue: 2015-05-04 106446_eng.xml Inductive sensor NJ5-18GK-N-5M ATEX 1D Instruction Manual electrical apparatus for hazardous areas Device category 1D for use in hazardous areas with combustible dust EC-Type Examination Certificate ZELM 03 ATEX 0128 X CE marking 0102 ATEX marking ¬ II 1D Ex iaD 20 T 108 °C (226.4 °F) Directive conformity 94/9/EG Standards IEC 61241-11:2002: draft; prEN61241-0:2002 type of protection intrinsic safety "iD" Use is restricted to the following stated conditions Appropriate type NJ 5-18GK-N... Effective internal capacitance C ≤ 70 nF ; a cable length of 10 m is considered. i Effective internal inductance L ≤ 50 µH ; a cable length of 10 m is considered. i General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Maximum housing surface temperature The maximum surface temperature of the housing is given in the EC-Type Examina- tion Certificate. Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related appara- tus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iaD. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079- 14 are met. The intrinsically safe circuit has to be protected against influences due to lightning. When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The appli- cable directives and standards must be observed. Maintenance No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. Special conditions Electrostatic charge The connection cables are to be laid in accordance with EN 50281-1-2 and must not normally be subjected to chaffing during use. Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 3 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com Release date: 2015-05-04 16:26 Date of issue: 2015-05-04 106446_eng.xml
Frequently asked questions
Why choose IPC Station?

What is IPC Station' warranty policy for the 106446?

What carriers does IPC Station use to ship parts?

Does IPC Station sell to international (non-USA) customers?

What methods of payment does IPC Station accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

Inductive Proximity Sensor, Rctnglr, DC, PNP, NO, 3 Wire, 10mm Range, Cable PUR, 2m, DC, Shielded In...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods